Current location - Recipe Complete Network - Catering franchise - 2021 first-class fire engineer exam "comprehensive ability" exam questions and answers (3)
2021 first-class fire engineer exam "comprehensive ability" exam questions and answers (3)

As an examiner who has taken countless exams, all of you should understand how much exam help the previous years' exam questions can provide for exam preparation in exam review! I'm in this from the 2022 first-class fire engineers exam only two months left for you to bring the 2021 first-class fire engineers exam, "Comprehensive Ability" exam questions and answers, quickly and I take a look at it!

61.Question stem a large commercial complex to carry out the old escalator demolition and replacement project, the unit of fire safety manager organization to carry out fire operations, the following measures do not comply with the "large commercial complex fire safety management rules for trial)" (Emergency Consumption [2019] No. 314) requirements are ( ).

Options

A. Electrical welders are licensed

B. Removal of flammable materials around the fire point

C. Arrangement of security guards and micro-fire station members for on-site supervision

D. Separation of the fire area and the business area with flame-retardant materials

Answer D

62.Question stem an important public **** building, the building height of 45m. a fire technical service organization of the building's fire water supply system testing, the roof of the high fire water tank room facilities in the test results do not meet the current national standards, "fire water supply and hydrant system technical specifications" (GB50974) is (). ).

Options

A. Water tank room set up pneumatic tank and pressure regulator pump, pressure regulator pump maximum number of times h

B. Water tank room set up a high fire tank, fire tank effective volume of 18m3

C. Pressure regulator pump suction pipe set up on the open-rod gate valves, muffler check valves and open-rod gate valves set up on the outlet pipe

D. Fire tank inlet pipe diameter DN32, fire tank filled with water for 7h

Answer B

63. The question of a unit of indoor fire hydrant system wall fire pump connector inspection, the following inspection results do not meet the current national standards for Fire water supply and fire hydrant system technical specifications" (GB50974) is ( ).

Options

A. The distance from the fire pump coupler to an outdoor hydrant is 20m

B. The fire pump coupler is installed under the glass curtain wall

C. The distance from the fire pump coupler to the safety exit of the exterior wall is 3.0m

D. The height of the fire pump coupler from the ground is 0.7m

Answer B

64.Question A fire technical service organization carries out a fire safety assessment of a commercial complex, and according to the "Trial Rules for Fire Safety Management of Large Commercial Complexes) (Emergency Consumption [2019] No. 314), the following information can be excluded from the "fire safety management situation" is ( ).

Options

A. Fire control room duty records

B. Fire inspection, inspection records

C. New fire products type inspection report

D. Fire safety training records

Answer C

65.Question stem a car garage 9 above ground, 3 underground, each floor height of 4m, a fire technical service organization to check the car garage, the following inspection results, in line with the current national standards "garage, garage, parking lot design fire code" (GB50067) is ( ).

Options

A. Above ground part of the outdoor evacuation metal ladder railing 杄 handrail height of 1.1m, inclined angle of 44 °

B. Above ground part of the use of closed stairwells

C. Underground part of the use of closed stairwells

D. Above ground part of the indoor evacuation staircase spacer wall to the handrail centerline of the width of 1.0m

D. Above ground part of the indoor evacuation staircase wall to the handrail centerline of 1.0m. Width of 1.0m

Answer A

66.Question stem a fire technical service organization of a high-rise building indoor fire hydrant system testing, the following test results, does not meet the requirements of the current national standards ( ).

Options

A. Fire pump control cabinets are set up in a dedicated fire pump control room, protection level of IP30

B. The system network in the state of steady state roof hydrant static pressure of 0.16MPa

C. Clearance height of 18m of the atrium of the fire hydrant and its fire lance filled with the value of the column of water is 10m

D. The system is equipped with a pneumatic water tank pressure regulator pumps start pumps for 10 times / h

Answer C

67. The question stem of a shoe workshop to be carried out in the fire extinguishing and emergency evacuation plan drill, the following drill implementation program, the content does not comply with the current national standards, "the fire extinguishing and emergency evacuation plan preparation and implementation of social units". and emergency evacuation plan preparation and implementation guidelines" (GB/T38315) is ( ).

Options

A. Inform all workshop employees of the specific time of the drill

B. Set the heating furnace device as the hypothetical site of the fire

C. Designate the deputy director of the workshop, Mr. Wang, to be responsible for recording the performance of the participants of the drill

D. Arrangements for people to act as an evacuation guide at the head of the stairs of each floor of the workshop

Answer B

68. The question stemmed from a fire technical service organization to a unit of fire extinguishers maintenance check, the following fire extinguishers can not be scrapped ( ).

Options

A. Factory period of just over 6 years of water-based portable fire extinguishers

B. Factory period of just over 10 years of portable carbon dioxide fire extinguishers

C. Nameplate off, can not be identified by the name of the manufacturer and the year of manufacture of the fire extinguishers

D. Portable ABC fire extinguishers burned < /p>

Answer B

69.Question stem Wang is the fire safety manager of a large commercial complex, according to the "fire safety management rules for large commercial complexes (for trial implementation)" (Emergency Consumption (2019) No. 314), the following job duties, belonging to the responsibilities that Wang should be fulfilled is ( ).

Options

A. Regularly organize the unit's fire work inspection and assessment

B. Establish the unit's fire archives, determine the unit's key fire safety parts

C. Establish the unit's fire safety work regular meeting system, regularly convene the regular fire work meetings

D. Coordinate the arrangement of the unit's operating Activities in the fire safety management

Answer B

70.stem an orthopedic hospital ward building height of 30m, with 100 beds. Hospital organization fire inspection, according to "high-rise civil building fire safety management regulations" (Ministry of Emergency Management Decree No. 5), the following inspection items can be excluded from the fire inspection content ( ).

Options

A. Fire, electricity, gas violations

B. Fire lanes are open

C. Fire facilities in good condition

D. Rectification of fire hazards

Answer D

The fire safety inspection of the building was carried out by the Ministry of Emergency Management. strong> 71.Question stem of a hospital ward building of automatic sprinkler system testing, open the end of the water test device, the wet alarm valve action, hydraulic alarm ringing, fire control room received pressure switch action signal, the fire pump did not start. Analyze the possible causes of the fire pump did not start, can be excluded ( ). strong> Answer B

72. The question of a shopping mall's mechanical smoke exhaust system testing, the following test results do not comply with the current national standards "building smoke exhaust system technical standards" (GB51521) ().

Options

A. Exhaust smoke and fire damper manual open flexible, closed reliably and tightly, the status of the valve closed signal feedback to the fire control room

B. Manually open the smoke valve, the fire control room to receive the smoke valve and the corresponding smoke exhaust fan action signal

C. Manually open the air supply outlet of the normal closure of the one, the corresponding D. Trigger a manual alarm button in a fire protection partition, the normally closed air supply and smoke vent in the same fire protection partition are linked to open

Answer D

73.The property unit of a large-scale commercial complex has prepared a fire extinguishing and emergency evacuation plan, and carried out a fire emergency evacuation plan drill. The fire emergency evacuation plan drill according to the "large commercial complex fire safety management rules (for trial implementation)" (Emergency Consumption [2019] No. 314), does not belong to the purpose of the plan drill ( ).

Options

A. Test the practicality and operability of the fire extinguishing and emergency evacuation plan

B. Test the unit's ability to deal with emergencies in an emergency situation

C. Test the familiarity of the person responsible for fire safety at all levels of the contents of the plan

D. Test the ability of shopping mall patrons to escape from the fire to save themselves

Answer D

74. A movie theater auditorium has 150 fixed seats. A fire technical service organization to the cinema inspection, the following inspection results, does not meet the current national standard "building design fire code" (GB50016) is ( ).

Options

A. The net width of the evacuation aisle in the auditorium is 0.90m

B. The net width of the auditorium of a safety exit is 1.45m

C. The net width of the auditorium side aisle is 0.80m

D. The cinema to the adjacent staging plaza of the outdoor evacuation aisles of net width 3.50m

Answer A

75.Question stem a fire technical service organization of an underground shopping mall in the evacuation of the aisles for inspection, the following results, in line with the current national standards, "building design and fire code" (GB50016) is ( ).

Options

A. Refuge aisle walls brushed with colorful paint

B. Business hall to the refuge aisle entrance to the front room of the use of the area of 5m2

C. Refuge aisle ceiling using calcium silicate board decoration

D. Business hall to the front room of the entrance to the refuge aisle door for the fire door of the B class

Answer C

76.The question of a public **** building fire supply and distribution system testing, the following test results, does not comply with the current national standards, "Building Design Fire Code" (GB50016) is ( ).

Options

A. The use of diesel generator sets as a backup power supply, diesel generator sets set up automatic and manual start device

B. Fire equipment power supply circuit in the building substation at the production and living electricity separate, self-contained system

C. In the air supply and smoke exhaust fan distribution lines at the last level of the switching box set up Automatic switching device

D. Fire distribution lines using fire-resistant cables, in the cable shaft and non-fire distribution lines laid in the same bundle

Answer D

77. The following results of the inspection, do not meet the requirements ( ).

Options

A. Workshop electrical wiring through the fire partition wall at the aperture of the non-combustible material blocking

B. Grinding machine is not directly grounded, the use of conductive materials indirect grounding

C. Workshop installation of the open side of the socket down, and the angle of 70 ° from the vertical plane

D. Operator's D. The operator's uniforms and shoes and hats are made of anti-static materials

Answer C

78. The question stemmed from a commercial complex property unit prepared a fire extinguishing and emergency evacuation plan, a clear fire-fighting action safety and security, protection, rescue and other groups and the duties of the members of the national standard according to the current "social units of the preparation and implementation of the guidelines for fire-fighting and emergency evacuation program. According to the current national standard "social unit fire extinguishing and emergency evacuation program preparation and implementation guidelines" (GB38315) belongs to the safety and security group responsibilities ( ).

Options

A. Rescue, escort the injured

B. Guarantee the supply of fire fighting equipment

C. Guarantee the commanding organization in the fire rescue agency's communication

D. Prevent unrelated people from entering the fire scene

Answer D

79. The question stemmed from the inspection of a shopping mall's emergency lighting and evacuation instructions system, the following findings do not comply with the current national standard "fire emergency lighting and evacuation instructions system technical standards" (GB51309) ( ).

Options

A. Smoke-proof stairwell anteroom emergency lighting fixtures on the ground for the lowest level of illumination is 5.01x

B. Smoke-proof stairwell emergency lighting fixtures on the ground for the lowest level of illumination is 12.01x

C. Evacuation aisles of emergency lighting fixtures on the ground for the lowest level of illumination is 3.01x

D. The lowest level of illumination of the emergency lighting in the business hall is 3.01x

Answer A

80. According to the current national standard, "Guidelines for the Preparation and Implementation of Fire Fighting and Emergency Evacuation Plans for Social Units" (GB/T38315), the fire fighting and emergency evacuation plan of a welfare institution may not include a specific plan. Emergency evacuation plan, may not be included in the plan "unit of basic information" is ( ).

Options

A. The main internal buildings, access to the adjoining situation

B. The city's annual dominant wind direction

C. The unit of the fire danger source situation

D. The surrounding 300m within the public **** fire safety facilities situation description

Answer B

Answer B

Answer B

Answer B

81.Question stem a covered commercial pedestrian street, both sides of the building are above ground 4-storey, building height of 23m, the building fire level for the second level, the fire inspection of the walk, the following inspection results, inconsistent with the requirements of the current home standards ( ).

Options

A. Walking on the upper part of the opening area of each layer of the floor for walking on the ground area of 35%

B. Walking street on both sides of the building of the stores using fire-resistant limit of 20Oh fire partition walls and fire shutters to separate

C. The first level of the side of the street to the side of the stores to use the eaves to prevent the fire from spreading vertically, the width of 1.0m. The width of the eaves is 1.0m

D. The closest distance between the two sides of the pedestrian street opposite the building is 10m

E. Between the stores facing the pedestrian street on the side of the installation of the width of 1.2m, the fire-resistant limit of 1.00 of the solid wall

Answer ABC

82. Rescue agencies in the jurisdiction of a number of units to carry out fire supervision and inspection, according to the current national standard "major fire hazards determination method" (GB-35181), the following results of the inspection, does not belong to the major fire hazards of the direct determination of the elements ( ).

Options

A. A kindergarten in the ground floor of the fourth floor to set up children's activities

B. An office building on the fire lanes illegally set up garbage room

C. Located in a shopping mall on the third floor of the movie theater is not set up independent evacuation staircase

D. A basement level of a cabaret is not set up automatic fire alarm system

E. A fire alarm system is not set up on the first floor of a cabaret

D. A fire alarm system is not set up in a basement level of a cabaret

E. A shopping mall fire alarm confirmation of the atrium of the electric smoke exhaust window can not be linked to open

Answer BE

83. The question stem of the automatic fire alarm system testing of a building, the following test results, in line with the current national standards "automatic fire alarm system construction and acceptance standards" ( GB 50166) are ( ).

Options

A. Above ground, four floors of a fire partition set up six manual fire alarm buttons, from any point to the nearest manual fire alarm buttons between the walking distance of 30m

B. Input module connected to the water flow indicator is independently installed in the wall next to the water flow indicator, and there are dimensions of 120mm x 120mm sign

C. The height of the bottom edge of the fire display panel installed on the wall of the evacuation aisle from the ground is 1.4m

D. The ambient noise sound pressure level of the first floor is 65B, and the sound pressure level of the standardized message broadcasting loudspeakers on that floor is measured to be a maximum of 75dB

E. The fire acoustic-visual alarm and the emergency evacuation indication signage fixtures are mounted on the same wall with a distance of 1.5m

E. The fire audible and visual alarms and the emergency evacuation indication signage fixtures are mounted on the same wall, with a distance of 1.5m between the two. 1.5m apart

Answer ABCE

84. Question stem a large commercial complex of the following practices, in line with the "large commercial complex fire safety management rules" requirements ().

Options

A. Evacuation diagrams in the public **** parts of the obvious location

B. Normally closed fire doors are set up on the correct opening and closing state of the logo

C. Before opening to the housing and urban-rural construction management department in accordance with the law to apply for fire safety inspections

D. The need to control the random access to the exit of safety Set up a push-latch type external door

E. Decoration before the front of the fire rescue agencies in accordance with the law for review and approval

Answer BD

85.Question stem a 4-story shopping mall on the ground, fire-resistant grade II, building height of 23.5m, shopping malls and a building adjacent to an office building, the height of the office building is 4.2m, fire-resistant grade two, a fire safety assessment of fire technical service organizations, found that the two buildings fire distance of 4.8m, does not meet the code requirements. The following rectification options, in line with the requirements of the current national standards ( ).

Options

A. shopping malls facing the office building side of the facade, which is 15m above the roof of the office building and the following part of the fire wall

B. shopping malls facing the office building side of the facade into the fire-resistant limit of 2.0h of the fire partition wall

C. office building facing the side of the mall facade into the fire wall. The roof of the office building does not have skylights

D. the shopping mall facing the office building side of the external wall, which is higher than the office building roof within the range of 15m and the following openings are set up Class B fire windows

E. shopping malls, office buildings adjacent to the external wall are not set up window openings, not set up the eaves

Answer AE

p> 86.Question stem a fire technical agencies of a building dry automatic sprinkler system inspection, maintenance, the following practices in line with the current national standards, "automatic sprinkler system construction and acceptance norms" (GB50261) have ( ).

Options

A. Monthly appearance of all the building nozzles and spare number of inspections, wells in a timely manner on the removal of nozzles on the foreign body

B. Weekly start and stop the system filling device, the system's inflatable value as well as accelerating the exhaust device to carry out a check

C. Monthly outdoor valve wells for water pipes on the C. Monthly inspection of control valves on the water mains in outdoor valve shafts to verify that they are fully open

D. Daily inspection of the system's dual-power inter-commissioning cabinets and control cabinets, and switching tests of the main and backup power supplies in the wells

E. Quarterly inspections of the water levels in fire fighting pools, fire fighting tanks, and the gas pressures in fire fighting pneumatic water supply equipment

Answer AD

87.Question A garment factory has prepared a fire suppression and emergency evacuation plan. The following emergency response measures, in line with the current national standard "social units fire extinguishing and emergency evacuation plan preparation and implementation guidelines" (GB/T38315) are ( ).

Options

A. A clear plan to dial "119" when the report of a fire alarm

B. Four-level plan clearly by the person responsible for fire safety to the scene of the command

C. The second level of the plan is clearly by the unit on duty on duty person in charge of the scene to the command

D. The second level of the plan is clearly by the unit on duty person in charge to the scene of the command

D. The second level of the plan is clearly by the unit on duty person in charge to the scene to the command <

D. Five-level plan to mobilize all the firefighting units to deal with

E. Three-level plan clearly by the fire safety manager to the scene of the command

Answer ABD

88. Question stemming from the fire rescue agencies to fire product supervision and inspection, the mandatory certification ( ).

Options

A. Filtered fire self-rescuing breathing apparatus

B. Fire doors

C. Sprinkler heads

D. Fire alarm controller

E. Cart fire extinguishers

Answer ADE

Answer ADE

strong> 89.Question A large commercial complex micro-fire station is equipped with fire fighting equipment. According to the "Large Commercial Complex Fire Safety Management Rules for Trial Implementation)" (Emergency Consumption (2019) No. 314), the following equipment belongs to the mandatory equipment of this micro fire station ( ).

Options

A. Intercom

B. Fire hose

C. Fire truck

D. Fire hose

E. Portable fire extinguishers

Answer ABDE

90 ...Question stem a fire facility maintenance and testing organization's legal representative Wang obtained the senior fire facility operator license certificate, did not obtain the certificate of registered fire engineers. The following status quo of the organization does not meet the requirements of the "Fire Technical Service Organization Practicing Conditions" (Emergency (2019) No. 88) ( ).

Options

A. The workplace has a floor area of 180m2

B. It is equipped with two project leaders who hold the certificate of registration of a first-class registered fire protection engineer

C. Wang Mou also serves as the technical leader

D. It has the legal personality of an enterprise

E. It has a fire protection facility operator National Occupational Qualification Certificate of personnel ****5 people

Answer ACE

91.stem of a high-rise shopping mall curtain wall and the threshold of the wall of the existence of the cavity, a fire service technical service organization of the cavity of the interlayer sealing burst fire inspection. The following inspection results, inconsistent with the current national standards "building fire sealing application of technical standards" (GB/T51410) ().

Options

A. In the building gap on the lower edge of the fire-retardant treatment of polyurethane as a backing material filler

B. Backing material filler height of 170mm

C. Backing material on top of the full coating of fireproof sealing paint

D. Backing material set up under the thickness of the steel support plate is 1.1m

D. Backing materials for the following 1.1m

E. The steel support plate under the backing material is sealed with fireproof sealant between the steel support plate and the curtain wall

Answer ABD

92. A fire protection technical service organization carries out testing on the fire doors, fire shutters and fireproof windows of a shopping mall. In line with the current national standards "fire shutter, fire door, fire window ground work and acceptance of the norms" (GB50877) ().

Options

A. movable fire windows on the temperature control release device action, movable fire windows in 50s automatically closed

B. normally open fire door in the fire partition of the two independent fire detector alarm, fire door closed

C. make an evacuation aisle on the 1 course of the fire shutter temperature release device action, the fire shutter automatically down

C. make an evacuation aisle on the 1 course of fire shutter release device action, the fire shutter automatically down The fire shutter is automatically lowered to 1.8m above the floor

D. After the alarm of one smoke detector in the fire protection sub-area which is specially used for linking fire shutters, the fire shutter in the evacuation aisle is lowered to 1.8m above the floor

E. After the alarm of two independent smoke detectors in the fire protection sub-area where the fire shutter is located, the fire shutter is lowered to 1.8m above the floor

E. After the alarm of two independent smoke detectors in the fire protection sub-area where the fire shutter is located, the fire shutter is lowered to 1.8m above the floor< /p>

Answer ADE

93.question a fire technical service organization of a convention and exhibition center international curtain exhibition building site for inspection, the following inspection results, does not comply with the "design of the building interior decoration fire code" (GB50222) have ().

Options

A. The construction and decoration materials of the booth use fire-resistant plastic decorative panels and glass fiber reinforced plastic

B. The distribution box at the bottom of the booth is laid on a metal support structure

C. The operating table of the restaurant's electric heating equipment in the showroom is made of flame-retardant phenolic plastics

D. Lighting rated at 60W is connected with the D. Rated power of 60W lighting and booth decorative curtains, curtains for the distance of 550mm

E. Exhibition racks installed on the tungsten halogen lamps backboard for plywood

Answer ACE

94. Question stem a high-rise office building underground garage with a pre-effective sprinkler system, the following results of the inspection of the system Meet the requirements of the current national standards ( ).

Options

A. No ceiling ceiling plate under the nozzle for the upright type, nozzle splash plate from the ceiling 100mm ~ 150mm

B. Nozzle using a square arrangement, the spacing of neighboring nozzles for 3.4m

C. vulnerable to collision, the nozzle selection of sprinkler head with a protective cover

D. The system is not set up to inflate the device

D. The system is not set up to inflate the device

D. The system is not set up to inflate the device. The system is not set up inflatable device

E. There are ceiling parts of the nozzle for the ordinary sagging sprinkler head

Answer ABC

95.Question stem a fire technical service organization of a gas fire extinguishing system to check the following inspection results, in line with the requirements of the current national standards are ( ).

Options

A. Collector pipe is fixed installed in the cylinder bracket, the pipe outside the red paint

B. Storage cylinder between the inward opening

C. Low leakage of high sealing valve is installed in the drive device outlet drive gas pipeline

D. Drive gas horizontal pipeline is fixed with a pipe clamp, the pipe clamp spacing is 0.5m

E. Select the valve operating handle is installed on the opposite side of the operating surface

Answer ACD

96.stem a fire technical service organization room on a large commercial complex to carry out fire safety assessment, the following results of the inspection comply with the "large-scale commercial complexes, fire safety management rules (trial implementation)" (emergency fire ()

Answer ACD

96. Trial)" (Emergency Consumption (2019) No. 314) requirements are ( ).

Options

A. The power outlet of the supermarket on the first floor is installed on the wooden decoration wall

B. The promotional banners in the shopping mall are made with combustible materials

C. The exhibition hall is set up with combustible and non-combustible materials to build and decorate booths

D. The open food processing area of the catering establishment uses open fire to process Food

E. Hotel rooms in the curtains and carpets with flame retardant products

Answer CE

97.stem of a complex building on the ground 22 floors, the height of each floor is 4m, the building fire-resistant grade for the first level, the building is equipped with elderly care facilities. A fire technical service organization of the elderly care facilities for fire inspection, the following results meet the code requirements ( ).

Options

A. Located on the fifth floor of a rehabilitation medical room set up rehabilitation beds 35

B. Located on the fourth floor of a chess and card activities room floor area of 280m2

C. Elderly care facilities are located in the floor location of the second to eleventh floors

D. D is located on the third floor of the dining room with the neighboring D. The dining room on the third floor is separated from the adjoining property office of the complex by a fire-resistant partition wall with a fire-resistance limit of 2.00h and a floor slab with a fire-resistance limit of 1.00h

E. An evacuation door is provided for the accommodation room for the elderly, which is situated on the sixth floor between the two safety exits, and has a floor area of 50m2

Answer CDE

98. An exhibition center of the smoke exhaust system debugging, the following debugging results in line with the current national standards "building smoke exhaust system technical standards" (GB51251) ().

Options

A. Trigger two independent fire detectors in the exhibition hall, the system sends out a fire alarm signal 35s after the exhibition hall air supply and the corresponding fan start

B. Manually open a normally closed air supply, the corresponding fan linkage to start the air supply and fan action signals fed back to the fire control room

C. Trigger a smoke partition of an exhibition center to debug the smoke exhaust system. Trigger two independent fire detectors in a smoke partition in the exhibition hall, the system sends out a fire alarm signal 35s later the movable smoke wall in the smoke partition is linked to fall into place

D. Manually turn on a smoke exhaust fan, the fan operates normally, the leaf rotates in the correct direction, and the fan operates smoothly without abnormal vibration and sound within 3.0h

E. Press the start button for a smoke exhaust fan in the fire control room, and receive the corresponding start button 8s later, and the action signal of the exhaust fan and fan is fed back to the fire control room

E. Manually open a normally closed air supply outlet, and the corresponding air supply outlet and air supply fan are activated. Start button in the fire control room, 8s after receiving the corresponding exhaust fan start signal

Answer BDE

99. stem Wang Mou for the shopping mall engineering department, responsible for the mall's daily maintenance of fire protection facilities, according to the "fire safety management of densely populated places," (XF654) the following does not belong to the Wang Mou should be fulfill the duties of ( ).

Options

A. Familiarize yourself with and master the functions and operating procedures of the fire facilities fire facilities

B. Preparation of the unit's fire extinguishing and emergency evacuation plan

C. In accordance with the system and procedures of the fire facilities to inspect and maintain

D. Conducting Fire inspection, make records

E. Do a good job of fire protection facilities operation, operation, failure records

Answer ACE

100.Question fire technical service organization of an indoor fire hydrant system testing, the following test results do not meet the current national standards for fire water supply and fire hydrant system technical specifications ("fire water supply and fire hydrant system technical specifications"). Fire hydrant system technical specifications" (GB50974) ().

Options

A. Fire pump outlet pipe installed on the test water pipe diameter DN50

B. Fire pump suction pipe control valve set up with the opening scale and sign of the concealed rod gate valve

C. Fire pump outlet pipe set up with a pressure gauge, open-rod gate valve, check valves

D. After opening the roof test hydrant, it takes 50s for the fire pump to start automatically and be put into normal operation

E. After the fire pump starts automatically, the pressure regulator pump continues to run

Answer BCD

What is the test for the first class fire protection engineer exam

Registered fire engineers a **** test three subjects, three subjects results validity retained for three years, meaning that three years through the three subjects can be examined. Three exams are "fire safety technical practice", "fire safety case analysis", "fire safety technology comprehensive ability"

"Fire safety technical practice" and "fire technology comprehensive ability" subjects of the examination questions for the objective questions. "Multiple choice questions" in each option, there are two or more options that meet the meaning of the question, wrong choice does not score; omission, each option selected 0.5 points. In all the multiple choice questions, there are 80 single choice questions, each question 1 point; 20 multiple choice questions, each question 2 points.

"Fire safety case study" subject examination 15 years of questions for the 6 subjective questions, subjective questions for the comprehensive case study questions; 2016 after the question type for the 2 multiple choice questions + 4 subjective questions, subjective questions for the comprehensive case study questions. The total marks for all three subject papers are 120. You need to score 72 marks or more (inclusive) in each subject.