One-star disinfection standard: it can kill representative strains such as Escherichia coli. During ozone disinfection, the ozone concentration in the disinfection cabinet should be greater than or equal to 20mg, and the disinfection time should be greater than or equal to 30min. During high-temperature disinfection, the disinfection temperature in the disinfection cabinet should be greater than or equal to 100 degrees Celsius, and the disinfection time should be greater than or equal to 15 minutes.
Two-star disinfection standard: in addition to eliminating Escherichia coli, disinfection targets also include representative strains such as "poliovirus". During ozone disinfection, the ozone concentration in the disinfection cabinet should be greater than or equal to 40mg/m3, and the disinfection time should be greater than or equal to 60min; During high-temperature disinfection, the disinfection temperature in the disinfection cabinet should be greater than or equal to 120 degrees Celsius, and the disinfection time should be greater than or equal to 15 minutes.
The new national standard clearly stipulates in the section of "signs and instructions" that the disinfection level of the disinfection cabinet should be marked on the front of the disinfection cabinet to show different disinfection effects. The disinfection effect of at least one room in the disinfection cabinet should reach the order of magnitude. One-star disinfection cabinet (room) is marked with disinfection star "*"; The two-star disinfection cabinet (room) is marked with a disinfection star "* *". The "Disinfection Star" sign shall not be used in the disinfection room that does not reach the disinfection level of the disinfection cabinet, and the use function of the room shall be marked.