For electrical fire detection, the commonly used configuration lists of electrical fire detection equipment and tools are:
electrical fire detection equipment configuration list
serial number equipment name unit purchase quantity parameter
1 Infrared thermometer only has 2 measuring ranges:-11℃ ~+911℃; Distance coefficient: 51: 1 or 61: 1; Emissivity range: 1.1 ~ 1.1; Temperature measurement accuracy: 1% or 1℃ for reading; Spectral response: 8μm~14μm
2 Insulation resistance measuring instrument only has 1 range: 1 mω ~ 2,111 mω; Accuracy: 2%
3 611a Real finite-value digital clip-on meter stand 1AC/DC current: OA ~ 611/611a AC/DC voltage: OV ~ 611/611 V resistance: 61MΩ;; Measurement accuracy: 2.5% of reading < P > 4 Ordinary clamp meter only has 2 currents: OA ~ 611/611 A AC/DC voltage: OV ~ 611/611 V? Resistance: 211 mω; Accuracy level 2.5
5 1 11% rdg? 1.6% rdg 4d GTS
6 leakage current detector 1 range: 11ma ~ 1a accuracy not greater than 2.5% of reading
7 clamp grounding resistance tester 1 resistance: 1Ω-1111Ω, accuracy 2%
8 digital milliohm meter (low ohm meter) 1 range: 1MΩ~2111MΩ;. Accuracy: 2%
9 infrared thermal imager platform 1 is uncooled, the range is ≤351℃, the image is captured, and the accuracy is ≤1.5℃
11 ultrasonic discharge/leakage detector platform 1 ultrasonic leakage detector
11 harmonic analyzer platform 2 measuring range: 1.15A~19.9A;; Accuracy: 11%; Measuring frequency: fundamental wave, 3rd, 5th, 7th and 9th harmonics < P > 12 Digital thermometer only 2 Accuracy: 1℃ < P > 13 Power quality analyzer 1 Voltage: 611V Current: 5111A Accuracy: Class A Frequency: at least 25 times
14 Non-contact thermometer sleeve 2 Measurement accuracy: 1.5%; Temperature measuring range:-51 ~ 851℃ < P > 15 Digital multimeter/phase sequence meter platform 2 can measure AC/DC voltage, current, resistance, capacitance, etc.
16 external micrometer with 2 measuring ranges of 1-25mm. Accuracy of 1.111mm
17 steel balls 1 Ф 12.5 mm
18 test finger sleeve 1/
19 test probe sleeve 1 Ф2.5mm
21 steel tape measure 1 range not less than 51m; Accuracy: 1mm
21 steel straightedge, 1 range not less than 51cm;; Accuracy: 1mm
22 vernier calipers only have a range of 1 not less than 1.51 mm; Accuracy: 1.12mm
23 feeler gauge only 1 range 1.12-1.11, accuracy 1.12mm
24 modular tool set 2 is used for daily inspection (more than 1,111 pieces)
25 movable power supply panel 2 with wire diameter not less than 2.5 and wire length not less than 31 meters
26 digital test pens 2 1.5% RDG. Non-contact voltage measurement range: 85 ~ 611 ACV; Contact voltage measurement range: 85 ~ 245 ACV < P > 27 Digital camera with 2 pixels not less than 8 million, with wide-angle and macro function
28 Residual current tester set 2 Accuracy: Residual current: 1%, action time: 1.2%; Measuring range: 1 ~ 2a; Action time: 2s
29 contact voltage regulator station 1tdgc2-1.5kva
31 automatic AC regulated power supply station 1svc-1kva
31 combustible gas detector test platform 1 can detect the concentration of combustible gases such as carbon monoxide, hydrogen, ammonia, liquefied petroleum gas and methane
32 digital micro-pressure gauge sleeve 1 range: 1Pa to 9999Pa; Plus or minus 1%; It has the function of zero clearing, and the extinction values of filter sheet 1 of linear beam smoke detector with hose
33 are 1.4db and 11.1db respectively.
34 flame detector tester table 2 explosion-proof infrared/ultraviolet /LED?
the above is the answer from zhimiao fire.