What is the process to do fire stores
What is the process of doing fire

This area is less than 300 square meters directly in the online office hall for the opening inspection can be more than 300 square meters need to be in the local administrative approval center for the fire window.

stores to do attic fire requirements

This original property license does not, can not build, belong to the illegal, this does not meet the fire requirements, according to the provisions of the format can be built not more than 20% of the room area of the region.

Just rented a store to install the fire hose need what process

Qualified design units out of the map - reported to the fire department for approval - out of the review comments - according to the review comments Modify the drawings - re-reported for review - agreed to the construction of the opinion - the original audit reported to the construction unit for archiving - Engineering construction - debugging - completion of the transfer of Party A - professional unit testing - test reports - report Audit unit acceptance - on-site acceptance - a qualified opinion - pre-opening fire inspection - agreed to Opinions on opening - opening

stores fire requirements

First, the following buildings should be set up DN65 indoor fire hydrant:

1, more than 5 floors or a volume of more than 10,000m3 of office buildings, school buildings, non-residential residential buildings and other civil buildings;

2, with indoor Fire hydrant with a crowded public **** building and other public **** building below the scale of the provisions of Article 8.3.1 of the Code should be set up fire hose reel; building area greater than 200m2 of commercial service outlets should be set up fire hose reel or lightweight fire hose.

Second, the following places should be set up automatic fire extinguishing system, in addition to water is not suitable to protect or extinguish the fire as well as other provisions of this specification, it is appropriate to use automatic sprinkler system:

1 any floor floor area of more than 1500m2 or a total floor area of more than 3,000m2 of the exhibition building, store, hotel buildings, and hospitals of the same building size of the ward building, outpatient building, Surgery Department; underground stores with a floor area of more than 500m2;

2, set up a centralized air-conditioning system with return air ducts (tubes) and a total floor area of more than 3,000m2 of the office building, etc.

Smoke control system

public **** building in the frequent stay of people or combustibles more than the ground floor room with a floor area of more than 300m2; the length of the inner aisle is more than 20.0m, the length of the inner aisle is more than 20.0m, the length of the inner aisle is more than 20.0m. 20.0m of internal walkways;

The following places shall be equipped with automatic fire alarm systems:

Shops, exhibition buildings, finance and trade buildings, passenger and freight buildings, etc. with a floor area of more than 3,000m2 on any floor or with a total floor area of more than 6,000m2;

Emergency fire lighting fixtures and lamps shall be set up:

Auditoria, exhibition halls, business halls, business halls, and business halls with floor areas of more than 400m2 shall be equipped with emergency fire lighting fixtures and lamps. 400m2 of exhibition halls, business halls, multi-function halls, restaurants, studio with a floor area of more than 200m2;

What is the fire building audit? What process is required

Article 10 In accordance with the national engineering construction fire safety technical standards need to carry out fire safety design of construction projects, in addition to the provisions of Article 11 of this Law, the construction unit shall obtain construction permits in accordance with the law within seven working days from the date of the fire safety design documents reported to the public security organs of the fire agency for the record, the public security organs of the fire agency shall be randomly inspected.

Article XI of the State Council public security departments of large crowded places and other special construction projects, the construction unit shall submit the fire design documents to the public security organs of the fire agency audit. The public security organs of the fire agencies responsible for the results of the audit according to law.

Article XII of the public security organs in accordance with the law should be fire protection agencies for fire design review of construction projects, without reviewing the law or review failed, responsible for approving the construction permit of the project shall not be given to the construction permit, the construction unit, the construction unit shall not be constructed; the other construction projects to obtain construction permits by the law of the unqualified spot check, shall stop construction.

Article 15 The construction unit shall apply for fire design review shall provide the following materials:

(a) construction fire design review application form;

(b) the construction unit's industrial and commercial business license and other legal identification documents;

(c) the design unit's qualification documents;

(d) the fire design documents;

(e) legal, administrative and other documents, such as the construction unit's license; (f) the construction unit's license and other documents, such as the fire design documents. p> (E) laws, administrative regulations and other materials.

In accordance with the law need to apply for planning permission for construction works, should provide construction planning permission documents; according to the law need to be approved by the competent department of urban and rural planning of temporary construction, belonging to the crowded places, should provide documents approved by the competent department of urban and rural planning.

9;

2. "Construction Project Completion Acceptance Fire Protection Filing Form"

3. Fire product inspection, stamped with the design qualification of the decoration unit. Audit Declaration Form"

7. A copy of the fire acceptance of construction works (buildings after 98 years);

8. A copy of the housing lease contract;

The second step: the fire acceptance of information

1. Project completion acceptance report;

2;

5 the following is a professional answer:

The first step. Four capacity building labeling

Third step fire opening inspection

1. "Fire Safety Inspection Declaration Form";

2. A copy of the business license or notice of pre-approval of the enterprise name issued by the industrial and commercial administrative organs;

3. A copy of the legal documents obtained in accordance with the law of the fire acceptance of the construction project or for the record;

4. . fire safety system, fire extinguishing and emergency evacuation plan;

6. fire products, decoration materials);

4. construction;

5: fire building review information

1. floor plan, supervision, testing unit's legal identification and qualification level documents. Construction Engineering Fire Protection Design Record Form

3. Business license or a copy of the approved name of the industry and commerce;

4. Design qualification documents;

5. Authorization letter of the applicant and a copy of the identity card of the appointee

6. Fire protection facilities, electrical . Staff pre-service fire safety education and training records and automatic fire system operators to obtain a copy of the fire industry-specific occupational qualification certificate. A copy of the authorization letter of the applicant unit and the identity card of the appointee.

For more fire knowledge, please visit this site, test reports (fire extinguishers, emergency lighting, safety evacuation signs . Completion drawings;

6. "Acceptance Declaration Form";

7. Application for the unit's power of attorney and a copy of the identity card of the appointee

8. Practitioner fire training certificate

Wanda's stores open fire to do what the certificate

July 26, Anhui Provincial Fire Brigade and the Fuyang City Fire Detachment of the Fuyang Yinzhou Wanda Plaza Shopping Center and Jiahua Hotel carried out fire inspection and acceptance work, and Fuyang Yingzhou Wanda Plaza conducted a field acceptance inspection. This marks the first Wanda Plaza in Fuyang ushered in a major construction node before the opening, and the prosperity of thousands of people will be brilliantly presented in front of the eyes of millions of Fucheng citizens on August 29th in advance of the opening.

200 square meters of stores need secondary fire

This according to the pattern needs to be changed directly after the fire opening inspection and can, do not need to declare.

The store interval mezzanine area can not exceed 25% of the area of the first floor, otherwise it is not allowed.