Maximum number of people in the shopping mall according to the "Building Design and Fire Prevention Code," Article 5.3.17, Item 5, "the number of evacuees should be calculated according to the floor area of each business hall multiplied by the area of the conversion value and the number of evacuees conversion coefficients. The area conversion value of above ground stores should be 50% to 70%, and the area conversion value of underground stores should not be less than 70%. The conversion factor for the number of evacuees can be determined according to Table 5.3.17-2. (5500/2)x0.5x0.85=1169
The maximum capacity of indoor amusement parks according to the "Building Design and Fire Prevention Code," Article 5.3.17, paragraph 4, "the number of evacuees from other entertainment venues should be calculated according to the floor area of the premises 0.5 people/m2;" the provisions of the determination. The number of evacuees shall be determined according to the floor area of the place. (5500/2)x0.5=1375 people