Maintenance fee standard
First, the maintenance fee of building fire control facilities is based on the annual fee.
Second, the maintenance cost of building fire control facilities is based on the maintenance cost of automatic fire alarm system, plus the maintenance cost of other related facilities, which is the total cost of the project.
Calculation formula: m = a+b+c+d+e+f.
Where: M= total maintenance cost of building fire control facilities.
A= Maintenance cost of automatic fire alarm system.
B= Maintenance cost of automatic fire extinguishing system.
C= Maintenance cost of flue gas control and extraction system.
D= Maintenance cost of fire shutter system
E= Maintenance cost of fire hydrant system
F= Maintenance cost of fire broadcasting and evacuation signs.
(1) The maintenance cost a of the automatic fire alarm system is calculated according to the number and scale of detectors and the service life of the system, as shown in the following table.
Unit: Yuan/detector
Year of use
charging standards
The number of detectors is greater than 1-3 years, 4-6 years and 7 years.
100 within 40.00 45.00 50.00
10 1-300 pcs 35.00 38.00 42.00
301-800 pcs 30.00 33.00 36.00
801-1500 only 25.00 27.00 30.00
150 1 above 23.00 25.00 27.00
(2) Other fire-fighting facilities of automatic fire-fighting system shall be calculated according to the maintenance cost of automatic alarm in its service area.
With automatic fire extinguishing system, b = 28% a;;
Equipped with smoke control system, c =10% a;
With fire shutter system, D=200.00 yuan × number of shutter doors;
E = 5% a has a fire hydrant system;
F=2%A, with broadcast and evacuation indication system.
Three, a single fire extinguishing system, the maintenance cost is calculated according to its protection area.
(a) a single automatic sprinkler system, according to the protection area, per square meter 1 yuan;
(two) a single gas fire extinguishing system, according to the protected space, calculated by 5 yuan per cubic meter;
Four, other building fire facilities maintenance costs, has been included in the above costs, no longer calculated separately.
5. The expenses listed above do not include the replacement of building fire control facilities and their accessories, statutory inspection and cleaning of fire detectors.
This charging standard for intransitive verbs is the highest charging standard, and the specific charges shall be determined by both parties through consultation.