How to find out which heating company the community is?
One is to call the maintenance company and ask which heating company it is. The second is to make a maintenance call and ask the customer service number, and then ask which heating company it is. Third, online inquiry, you can check the website of the management Committee and call the heating company of the management Committee.
The Code for Design of Heating, Ventilation and Air Conditioning clearly stipulates the design temperature of indoor heating: in heating design, the indoor calculated temperature in winter should be determined according to the building use, and16-24℃ should be adopted for the main room of civil buildings; What is the temperature of the bathroom auxiliary building and auxiliary room? 25℃, locker room? 25℃, office and lounge? 18℃, canteen? 18℃, toilet and toilet? 12℃。
Heating temperature requirement
1. Indoor temperature: the suitable range of central heating room temperature is 16 ~ 20℃, and that of decentralized heating room is 13 ~ 17℃, and the indoor temperature in any area shall not be lower than 65438+.
2. Vertical temperature difference: refers to the difference between the temperature at 0. 1m above the central floor of the living room and the temperature at 1.5m above the floor. The vertical temperature difference is too large, the foot temperature drops, and the body temperature regulation is tense, which is not conducive to health. General vertical temperature difference should be less than 3℃.
3. Horizontal temperature difference: refers to the temperature difference between points in the living room1.5m.. Generally, it is easy to catch cold in doorways, windows, corridors and other places, and the indoor horizontal temperature difference is too large, so the horizontal temperature difference should not exceed 2 ~ 3℃.
4. The Indoor Air Quality Standard (GB/T 18883-2002) clearly stipulates that the heating temperature in winter is 16-24℃, and the indoor temperature meeting this standard is comfortable. .
5. The Design Standard for Building Energy Efficiency (GB 50 189-2005) stipulates different indoor temperature standards for different building types, such as office, sports, commerce and catering.
The above is mainly based on how to find out which heating company the community is. We can call customer service or check online directly, because it is the Internet age, and it may be much more convenient to check online directly. Not only that, it also tells you what the temperature requirement for heating is, and we need to see if the temperature at home has reached this level.