According to the Ministry of Public Security Order No. 61, the enterprise should be at least how often a fire inspection
Based on the Ministry of Public Security Order No. 61, the public gathering places in the business period of fire inspection should be at least once every two hours. In order to strengthen the management of fire safety, to ensure that national property and people's lives from harm, the implementation of the "prevention-oriented, prevention and elimination of combining" fire policy, enhance the "sense of concern", the fire of all types of fire hazards, the implementation of the principle of fire prevention of fire safety, special Develop this fire safety responsibility. Article I? Responsible person has the following fire prevention duties (responsible person refers to all employees in the factory): a, *** with the study, fire regulations and company rules and regulations. The company laid out the fire prevention work, the development of the signing of this fire safety responsibility, and cascade to the shift. Second, publicize the fire regulations and fire safety system, employees consciously abide by, so that it is always fire, everywhere fire, "worry awareness". Third, the office staff often staff dormitories, workshops and other factories within the power supply, flammable, explosive substances and electrical equipment safety checks or inspections, hidden dangers to eliminate, and corrective measures. Four. "No smoking" regulations, smoke-free dormitory, smoke-free workshop, to take mutual supervision, office personnel from time to time to check. And according to the rules and regulations of the company, the factory personnel smoking violations depending on the severity of the case for a fine or dismissal. Fifth, the factory security personnel in the regional scope of regular maintenance of fire equipment, expired or damaged fire equipment, should be immediately replaced or rectified. Sixth, fire or fire, should be organized to fight, not to delay the war, the police 119. seventh, the office in charge of fire safety responsibility, should be fire and fire safety accounts, inspection records, rectification of hidden dangers have archives, and security personnel signed a letter of responsibility. Article II? Office responsible person fire prevention scope I. Scope: . Belongs to the jurisdiction of the warehouse, workshop, cafeteria, staff quarters, offices and temporary stacking of items simple shed, items stacked on the ground, waste paper piles and so on. Article 3? Employee's legal responsibility I. For violation of the terms of this responsibility, criminal penalties, according to the company's safety and fire prevention system and the company's staff dismissal regulations for disposal. Second, dereliction of duty, violation of fire regulations of the terms of this responsibility, to the property and life of serious harm, criminal offense, transfer to justice, according to the law to investigate criminal responsibility. Third, the person responsible for safety, can be based on this responsibility, the development of implementation rules. Fourth, the responsibility of the book in triplicate, each side of a copy, archive a copy. Fire fighting system 1. seriously study and implement the "Fire Protection Law" and the Ministry of Public Security Order No. 61, increase publicity, training efforts, the staff of the general knowledge of fire fighting education, so that all employees are familiar with the general knowledge of fire fighting, so that everyone is responsible for the fire fighting work of the enterprise. 2. clear tasks, the implementation of the responsibility for signing the safety and fire prevention responsibilities at each level, in accordance with who is in charge of who is responsible for the work of the principle of real fire fighting work into effect. 3. increase the inspection, the responsibility for the implementation of the fire fighting work. 3. Increase the inspection and rectification efforts, in addition to the weekly organization of special inspections. Rectification efforts, in addition to the weekly organization of special inspections, every day there should be a three-tier inspection system of the Ministry of Security to check the safety and fire prevention, found that the problem, timely reporting, timely treatment. 4. Annual organization of fire fighting and evacuation drills not less than two. 5. Do a good job of fire prevention during the major festivals, and to develop a specific security program. 6. Strengthen the fire source, the management of the power supply, and the implementation of a natural gas, liquefied petroleum gas inspection system, electrical and electronic equipment, and the implementation of fire prevention. Strengthen the fire source, power management, the implementation of natural gas, liquefied petroleum gas inspection system, electrical wiring and equipment inspection system, clear fire hazards in a timely manner. 7. Establishment of corporate fire archives, the formation of volunteer fire department, prevention-oriented, prevention and elimination of combinations. 8. Strengthen the smoking management system, shopping malls for smoke-free shopping malls prohibit smoking. 8. Adhere to do a good job of safety exits, evacuation routes of the special management and inspection of the work of the fire or fire line hidden danger rectification and improvement of untimely departments, will double the punishment of the responsible person. 9. Guarantee that the fire protection facilities and equipment in place, intact and good, in line with the requirements of the laws and regulations, and the implementation of the maintenance of responsible persons. 10. Fire monitoring center shift handover system a. Shift personnel must arrive at their posts fifteen minutes in advance, ready for handover.? Second, before going on duty must be dressed in accordance with the regulations, check the appearance of instrumentation, good spirit. Third, check the post of the equipment is running well and handing over the inspection tour, the executive machine notes. Fourth, on-duty personnel must record the book to fill out the equipment operation, inspection and other conditions, and requires clear handwriting, complete records. Fifth, the fire emergency tools, related information such as the number of neatly arranged in accordance with the regulations. Sixth, do a good job in the control room health cleanup, to ensure that the machine, the ground, the wall is clean. Seven, the shift personnel did not arrive, the staff shall not leave the post, should be timely to the relevant leadership report, please ask for instructions on how to deal with it. Eight, the contents of the shift handover after confirmation must be signed in the shift handover book and time, to show that the confirmation and responsible for. Nine, such as encountering emergencies and other special circumstances, the successor to assist the shift handler to deal with the incident, to be the end of the incident handling, by the higher leadership approval, and then the shift handover. Ten, the receiver is drunk, emotionally unstable, consciousness, shall not hand over the shift, should be reported for instructions on how to deal with eleven, shift handover should be carried out in accordance with this system, such as not in accordance with the provisions of the office, the receiver can put forward the views of the shift handover personnel required to make up for the office immediately, or not to take over the shift, and to the relevant leadership report. Twelve, the fire control room two-person executive, not a single handover executive, not telephone credibility handover, should be reflected in writing. Fire monitoring center safety inspection system 1, fire inspection every two hours should include:?A fire, electricity with or without violations: malls for smoke-free shopping malls prohibit smoking, prohibit the use of fire; catering fire: microwave ovens, stoves, no flammable and combustible hazards within 1 meter, the net distance between the stove and the gas cylinder shall not be less than 0.5 meters, the stove and the gas cylinder connected to the length of the hose shall not exceed 2 meters. The hose should be frequently checked, regularly replaced, ignition need to use the ignition rod, the end of the fire gas valve closed in a timely manner, the operating room of the fume hood and flue inlet within 1 meter, should be cleaned daily. Exhaust fume pipe should be cleaned at least once every 60 days, cleanup should be well documented; construction fire: fire certificate, clear professional qualifications fireman, fire watchman, fire extinguishers, fire prevention boards and other precautions are equipped, the site whether there are chemical hazards, there is no oil cross operation, fire welding machine 2, 5 meters shall not be combustible flammable materials, fire shall not be left within 30 minutes after the fire to do a good job cleaning up not to leave embers; electricity Prohibit the arbitrary pulling and tearing of wires power supply, laying electrical lines should be approved by the design, engineering, security department approved by the professional licensee according to the power of the electrical equipment, the number of units to use the national requirements of the standard wire equipment, the mall distribution line must use rubber jacket wire prohibit the use of twisted wire and other simple hazardous materials. B safety exits, evacuation routes are open, safety evacuation signs, emergency lighting is intact: Safety exits shall not be closed, blocked, safety exits shall not be set at the threshold, the evacuation door should be opened to the direction of evacuation, shall not use the rolling door, turnstile, hanging door, side pull door. Steps shall not be set within 1.4 meters inside and outside the door. Indicator signs shall be set on the top of the safety exit and the evacuation channel and its corners on the wall less than 1 meter above the ground level; the spacing of the indicator signs set on the evacuation channel shall not be more than 10 meters. Business area of the safety exits, evacuation routes and key areas should be set up emergency lighting. Emergency lighting of continuous illumination time shall not be less than 20 minutes, the minimum illumination of the ground shall not be less than 0.5 lux. The main evacuation channel should lead directly to the safety exit, and its width shall not be less than 2.4 meters; the width of the auxiliary evacuation channel shall not be less than 1.5 meters. No stalls shall be set up or goods shall be piled up in the evacuation passage. C fire facilities, equipment and fire safety signs are in place, complete: no store, individual shall not damage or unauthorized misappropriation, demolition, deactivation of fire facilities, equipment, shall not be buried, encircled, cover the fire hydrant, shall not occupy the fire spacing, blocking the fire truck channel. Doors and windows of crowded places, shall not be set up to affect the escape and fire fighting and rescue obstacles , fire hoses in the fire hydrant. Fire fighting system 1. Study and implement the "Fire Protection Law" and the Ministry of Public Security Order No. 61, increase publicity, training, education of general knowledge of fire fighting for employees, so that all employees are familiar with the general knowledge of fire fighting, so that everyone is responsible for the fire fighting work of the enterprise. 2. Clearly define the task, implement the responsibility, sign the safety and fire prevention responsibility book at each level, in accordance with who is in charge of who is responsible for the work of the principle of real fire fighting work to the real situation. 3. 3. Increase the inspection and rectification efforts, in addition to the weekly organization of special inspections. Rectification efforts, in addition to the weekly organization of special inspections, every day there should be a three-tier inspection system of the Ministry of Security to check the safety and fire prevention, found that the problem, timely reporting, timely treatment. 4. Annual organization of fire fighting and evacuation drills not less than two. 5. Do a good job of fire prevention during the major festivals, and to develop a specific security program. 6. Strengthen the fire source, the management of the power supply, and the implementation of a natural gas, liquefied petroleum gas inspection system, the electrical work of the company. Strengthen the fire source, power management, the implementation of natural gas, liquefied petroleum gas inspection system, electrical wiring and equipment inspection system, clear fire hazards in a timely manner. 7. Establishment of corporate fire archives, the formation of volunteer fire department, prevention-oriented, prevention and elimination of combinations. 8. Strengthen the smoking management system, shopping malls for smoke-free shopping malls prohibit smoking. 8. Adhere to do a good job of safety exits, evacuation routes of the special management and inspection of the work of the fire or fire line hidden danger rectification and improvement of untimely departments, will double the punishment of the responsible person. 9. Guarantee that the fire protection facilities and equipment in place, intact and good, in line with the requirements of the laws and regulations, and the implementation of the maintenance of responsible persons. 10. Fire monitoring center shift handover system a. Shift personnel must arrive at their posts fifteen minutes in advance, ready for handover.? Second, before going on duty must be dressed in accordance with the regulations, check the appearance of instrumentation, good spirit. Third, check the post of the equipment is running well and handing over the inspection tour, the executive machine notes. Fourth, on-duty personnel must record the book to fill out the equipment operation, inspection and other conditions, and requires clear handwriting, complete records. Fifth, the fire emergency tools, related information such as the number of neatly arranged in accordance with the regulations. Sixth, do a good job in the control room health cleanup, to ensure that the machine, the ground, the wall is clean. Seven, the shift personnel did not arrive, the staff shall not leave the post, should be timely to the relevant leadership report, please ask for instructions on how to deal with it. Eight, the contents of the shift handover after confirmation must be signed in the shift handover book and time, to show that the confirmation and responsible for. Nine, such as encountering emergencies and other special circumstances, the successor to assist the shift handler to deal with the incident, to be the end of the incident handling, by the higher leadership approval, and then the shift handover. X. If the shift receiver is drunk, unstable, or unconscious, he/she shall not hand over the shift and shall report to the superior for instructions on how to deal with the situation. XI, the shift handover should be in accordance with this system, such as not in accordance with the provisions of the office, the receiver can put forward the views of the shift handover personnel immediately required to make up for, otherwise you can not take over the shift, and to the relevant leadership report. Twelve, the fire control room two-person executive, not a single handover executive, not telephone credibility handover, should be reflected in writing. Fire monitoring center safety inspection system 1, fire inspection every two hours should include: A fire, electricity, there is no violation of the rules: shopping malls for non-smoking shopping malls prohibit smoking, prohibit the use of fire; catering fire: microwave ovens, stoves within 1 m shall not have flammable combustible hazards, stoves and gas cylinders between the net distance of not less than 0.5 meters, stoves and gas cylinders connected to the length of the hose shall not exceed 2 m. The hose should be checked frequently and replaced regularly. The hose should be frequently checked, regularly replaced, ignition need to use the ignition rod, the end of the fire gas valve closed in a timely manner, the operating room of the fume hood and flue inlet within 1 meter, should be cleaned daily. Exhaust fume pipe should be cleaned at least once every 60 days, cleanup should be well documented; construction fire: fire certificate, clear professional qualifications fireman, fire watchman, fire extinguishers, fire prevention boards and other precautions are equipped, the site whether there are chemical hazards, there is no oil cross operation, fire welding machine 2, 5 meters shall not be combustible flammable materials, fire shall not be left within 30 minutes after the fire to do a good job cleaning up not to leave embers; electricity Prohibit the arbitrary pulling and tearing of wires power supply, laying electrical lines should be approved by the design, engineering, security department approved by the professional licensee according to the power of the electrical equipment, the number of units to use the national requirements of the standard wire equipment, the mall distribution line must use rubber jacket wire prohibit the use of twisted wire and other simple hazardous materials. B safety exits, evacuation routes are open, safety evacuation signs, emergency lighting is intact: Safety exits shall not be closed, blocked, safety exits shall not be set at the threshold, the evacuation door should be opened to the direction of evacuation, shall not use the rolling door, turnstile, hanging door, side pull door. Steps shall not be set within 1.4 meters inside and outside the door. Indicator signs shall be set on the top of the safety exit and the evacuation channel and its corners on the wall less than 1 meter above the ground level; the spacing of the indicator signs set on the evacuation channel shall not be more than 10 meters. Business area of the safety exits, evacuation routes and key areas should be set up emergency lighting. Emergency lighting of continuous illumination time shall not be less than 20 minutes, the minimum illumination of the ground shall not be less than 0.5 lux. The main evacuation channel should lead directly to the safety exit, and its width shall not be less than 2.4 meters; the width of the auxiliary evacuation channel shall not be less than 1.5 meters. No stalls shall be set up or goods shall be piled up in the evacuation passage. C fire facilities, equipment and fire safety signs are in place, complete: no store, individual shall not damage or unauthorized misappropriation, demolition, deactivation of fire facilities, equipment, shall not be buried, circled, blocking the fire hydrant, shall not occupy the fire spacing, blocking the fire truck channel. Doors and windows of crowded places, shall not be set up to affect the escape and fire rescue obstacles, fire hydrant fire hose, water belt, gun must be good in place, fire extinguishers annual inspection is effective, seal intact, pressure standards, fire equipment, equipment and facilities, shall not be used in matters unrelated to the fire fighting and rescue work D normally closed fire doors are in a closed state, whether the fire shutters are stacked under the items affecting the use of the fire shutter: The use of shopping malls is Class A (90 minutes) fire doors Check whether the door closer and the paracord are intact, and whether articles shall not be piled up under the fire shutter at 1 meter to affect the use. e Personnel on duty in key fire safety areas: the implementation and management of personnel responsibilities in the power distribution room, engine room, storehouse and kitchen. The items in the warehouse should be stacked in pallets, and each pallet should not cover an area of more than 100 square meters. And ensure that the "five distance": the distance between stacks should not be less than 1 meter, the distance between stacks and walls should not be less than 0.5 meters, the distance between stacks and beams should not be less than 0.3 meters, the distance between stacks and columns should not be less than 0.3 meters, the distance between stacks and lights should not be less than 0.5 meters. The width of the main channel in the warehouse should not be less than 2 meters. Stock items shall not be placed in a way that crowds out or affects the use of fire fighting facilities and equipment. Treasury is not allowed to use tungsten iodine lamps and incandescent lamps over 60 watts and other high-temperature lighting. When using fluorescent lamps and other low-temperature lighting fixtures, the ballasts should be insulated, heat dissipation and other fire prevention measures; ballasts should not be set in the boring roof. It is not allowed to set up mobile lighting fixtures in the warehouse. Lighting fixtures vertically below the horizontal distance from the stored items should not be less than 0.5 meters. 2, the inspector should correct the violations in a timely manner, properly dispose of fire hazards, can not be disposed of on the spot, it should be immediately reported. The discovery of an incipient fire should be immediately reported to the police and promptly put out. You can call the central control (*****) fire (119) phone, you can press the nearest fire alarm button to call the police. 3, fire prevention inspections, inspections should be filled out, inspection records, inspections, inspectors and their supervisors should be in the inspection, inspection records on the signature, archives for inspection. 4, the inspection staff is the Security Department of the security forces, in case of suspicious people suspicious things to have to follow up with a handover to the store, personal violations, dangerous behavior (smoking), and the police should be able to find out what is happening in the store. Violations, dangerous behavior (smoking, photography, roller skating, with pets, stay in the channel for a long time, distribution of advertisements, customer service surveys, unauthorized picking of the news media, customer disputes, customer complaints, unauthorized construction, hazardous handling, poor attire, brawl, etc.) should be promptly found, inquired about, and stop, to ensure that the rights and interests of lawful persons, to maintain the orderly business environment of the shopping mall. Passage with or without debris door locks bar push whether intact. Security duty pay attention to self-protection. 5, the inspection staff is prohibited to use the work time to gossip or do private business, shall not enter the independent management of the region, the work needs, should be more than two people by the supervisor, the person in charge of the region agreed to enter, and cooperate with the person in charge of the work. Fire monitoring center work system I. Strictly abide by national laws, regulations and the company's rules and regulations. Understand and master the fire alarm control equipment and facilities of various performance indicators and operating methods, familiar with the relevant professional theoretical knowledge and safety regulations, licensed to work; Second, stick to their posts, always maintain a high degree of vigilance. Monitor the fire alarm control and monitoring equipment and facilities, operate in strict accordance with the procedures, seriously deal with the events of the shift, and truthfully recorded; three, regular inspection of the fire control room equipment and communication equipment, etc., regularly do the function of each system test, maintenance and other work to ensure that the fire protection facilities are in good operating condition; four, to maintain indoor cleanliness and hygiene, facilities and equipment without stains, no dirt, indoor items are neatly arranged, Walls, floors clean; proper storage and use of control room equipment and facilities and a variety of public goods, to prevent loss and damage, and do a good job of receiving and borrowing registration; five, when the fire alarm occurs, the correct and timely operation of the use of fire alarm control equipment and facilities, and in accordance with the provisions of the alarm program in a timely manner to notify the relevant departments and persons in charge; after the fire is confirmed, according to the requirements of the correct start-up and shutdown of the relevant fire equipment and facilities, cooperate with the organization of fire-fighting work; six, with the organization of the fire. Cooperate with the organization to extinguish the fire; Sixth, when the equipment and facilities are found to be faulty, notify the duty leader and engineers and technicians for repair and maintenance in a timely manner, and shall not dismantle, misapply and deactivate the equipment and facilities without authorization. Take the initiative to cooperate with the relevant personnel to carry out maintenance and repair of equipment and facilities and truthfully registered; seven, give full play to the advantages of the monitoring system, pay close attention to all kinds of situations in the shopping mall, pay attention to the discovery of suspicious people or suspicious things. Discovery of abnormalities should be promptly reported to the duty leader, in accordance with the operating procedures to take decisive countermeasures, shall not be paralyzed and delayed;? Eight, do a good job in the control room confidentiality. Unrelated personnel are prohibited from entering the fire control room, the need to enter the monitoring room for work, subject to the consent of the manager of the Security Department before entering, the duty officer should be well documented; IX, carefully fill in the duty period of the relevant facilities and equipment operation records, the situation and the results of the treatment. The shift is not dealt with should explain the successor to continue to follow up, and do a good job handing over the goods; 10, to complete the leadership of the other tasks. Fire monitoring center watchman system I. The watchman must stick to his post and shall not be absent without leave. According to the provisions of the punctual pickup, patrol, conscientiously implement the duties of the post, in addition to floor patrol and police, the duty officer shall not do things unrelated to their work; Second, the duty officer shall not have to be absent without cause and private shift, due to special circumstances urgent need for shift, the duty officer must be three days in advance to the fire foreman to apply for and fill out the "shift application form", reported to the department head agreed to before the shift can be changed, the duty officer shall be the first time, and then the fire department shall be the only person who has the right to apply. Only after reporting to the head of the department can he/she transfer to another shift. If a major accident occurs during the shift change, the person on duty should be mainly responsible; Third, actively cooperate with the security guards to do a good job in their daily work, when an emergency occurs, if the watchman is unable to deal with it or exceeds the terms of reference should be reported to the leadership of the company in a timely manner in accordance with the procedures, the watchman shall not take the lead without authorization; Fourth, the establishment of a sound work record system, the watchman should be my name, date, shift, fire monitoring system operation, The watchman should record his name, date, shift, operation of the fire monitoring system, duty situation and matters to be followed up in detail, and seriously do a good job of handing over; V. Unrelated personnel shall not enter the control room without authorization, such as the company leadership approval, the control staff should strictly implement the guest registration system; VI. The watchman should take the initiative to undertake the health and cleaning work in the control room, tools and supplies will be neatly arranged, and the daily cleaning of the floor, the floor, the indoor equipment and facilities, equipment, desks, chairs and doors, windows and glass, indoor equipment must not have dust and dirt and the indoor equipment. The indoor equipment must not have accumulated dust and stains; vii. During the work period, they must not make private calls, play games, read books and magazines, smoke, drink or sleep. Strictly prohibited in the control room to eat; eight, pay attention to appearance, maintain a good state of mind, according to the provisions of the dress and carry duty supplies. Nine, carefully fill out the duty period related facilities and equipment operation records, the situation and the results. The shift has not been dealt with should be explained to the successor to continue to follow up, and do a good job of handing over the goods.