Current location - Recipe Complete Network - Catering franchise - What's wrong with the Jinzao d330 boot flash 32?
What's wrong with the Jinzao d330 boot flash 32?
Haotaitai induction cooker code

E0 has no pot.

E2 sensor is open or short.

E3 voltage high (260 volts)

E4 voltage is not high (170V)

E5 anti-combustion

The internal temperature of E6 machine is too high.

Hao Di induction cooker

E2 temperature sensor

E3 high voltage protection

E4 voltage is too low.

The surface temperature of E5 furnace is too high.

The temperature in E6 machine is too high, the air outlet is blocked and the fan is broken.

Vantage induction cooker fault code

E0 IGBT overtemperature

E 1 no pot

E2 voltage is low

E3 voltage is high

E6 Guo gan Shao

E7 IGBT thermal open circuit

E8 IGBT thermal short circuit

E9 Furnace Surface Thermal Open Circuit

E 10 furnace surface thermal open circuit

Judgment and maintenance of common simple faults in Haoda

Fault 1. When the plug is plugged in, the sound of "Bibi" cannot be heard, and the display screen is not lit when the "On/Off" key is pressed.

Fault inspection: whether the plug or socket is in good contact. 2. Whether there is power failure. 3, switch socket, fuse, power cord are in good condition.

Fault 2, continuous short "beep" sound, warning stops after 30 seconds.

Fault inspection: whether the pot used is appropriate; Whether the pot is placed in the center of the flat plate; Is the area diameter of the pot bottom greater than?

12CM or more.

Fault 3: The heating stops suddenly during use.

Fault check: whether the ambient temperature is high; Whether the air inlet and air outlet are blocked; When the temperature is maintained, it means that the set temperature has been reached; Sometimes the protection device works, waiting for a few minutes to confirm.

Fault 4 (insulation) The temperature cannot be controlled during use.

Fault inspection: whether the bottom of the pot used is uneven and whether the center is sunken.

Common fault codes and fault phenomena

Common fault code E 1 fault phenomenon: IGBT sensor fault.

Common fault code E 2 fault phenomenon: induction fault of furnace surface diameter

Common fault code E 3 fault phenomenon: input voltage is too high

Common fault code E 4 fault phenomenon: input voltage is too low

Common fault code E 5 fault phenomenon: the induced temperature on the furnace surface is too high

Common fault code E 6 fault phenomenon: IGBT temperature is too high

Common fault code E 0 fault phenomenon: no pot or pot mismatch.

Fault code of Jiuyang induction cooker:

E0 internal circuit failure;

E 1 No pot or pot (material, size, shape, location) is not suitable.

E2 The internal heat dissipation of the machine is poor or the internal temperature sensor is faulty.

E3 grid voltage is too high;

E4 grid voltage is too low;

E5 ceramic plate temperature sensor is damaged.

E6 cookware is dry-burned, and the cookware temperature is too high;

E8 key is turned off due to moisture or dust inside the machine.

Jiuyang JYC- 18B Fault Code

E0 internal circuit fault

E 1 No pot or pot [quality/size/shape/position] is not suitable.

E2 The internal heat dissipation of the machine is poor or the internal temperature sensor is faulty.

E3 grid voltage is too high.

E4 grid voltage is too low.

E5 ceramic plate temperature sensor is damaged.

E6 cookware is dry-burned, the cookware temperature is too high, and the ceramic plate temperature sensor is short-circuited.

Jiuyang JYC- 18D

E0 internal circuit fault

E 1 The function light flashes, warning that the pot is not placed or the pot is too small.

The E2 machine is overheated, the tuyere is blocked, the fan does not turn, and the IGBT temperature sensor is open or short-circuited.

E3 voltage is too high.

E4 voltage is too low.

E5 ceramic plate temperature sensor is open.

E6 ceramic plate temperature sensor is short-circuited.

Jiuyang JYC- 19AS8

E0 internal circuit fault

E 1 The function light flashes, warning that the pot is not placed or the pot is too small.

The E2 machine is overheated, the tuyere is blocked, the fan does not turn, and the IGBT temperature sensor is open or short-circuited.

E3 voltage is too high.

E4 voltage is too low.

E5 ceramic plate temperature sensor is open.

E6 cookware is dry-burned, the cookware temperature is too high, and the ceramic plate temperature sensor is short-circuited.

E8 is wet or dirty inside.

Jiuyang JYC- 19D fault code

E0 circuit internal fault,

E 1 Do not check the pot,

E2 machine is overheated inside,

E3 voltage is too high,

E4 voltage is too low,

E5 temperature sensing is turned on,

E6 temperature sensor short circuit

Fault code of golden stove induction cooker

Fault Code of Jinzao KJ- 12E Disinfection Tea Making Furnace

E 1 power supply voltage is too high.

E2 supply voltage is too low (even if the fan is turned on)

E3 furnace plate temperature sensor is open.

E4 furnace surface temperature is too high.

E5IGBT sensor open circuit

E6 furnace temperature is too high.

Kaiteng induction cooker fault code:

E 1 line fault

E2 power supply voltage is too low or too low.

Fault of IGBT temperature sensor of E3 power tube.

E4 bottom sensor is not faulty.

Fault code of Kezhixing induction cooker produced by Kezhixing Electric Appliance Factory in Huangpu Town, Zhongshan City;

EO: The pot is wrong.

E 1: undervoltage

E2: Overvoltage

E3: Overstability Protection

E4: Power mismatch

E5: Boiler overtemperature

E6: Whether the pot is empty or not, select the heat preservation function.

Fault code of Kelitai induction cooker

E 1 no-load protection

E2 gate voltage is low.

E3 grid voltage is high.

E4 furnace surface temperature is high.

E6 furnace air burning

E0 machine temperature is high.

Kono induction cooker fault code:

E0: Pots could not be detected.

E 1: (same as E6) IGBT overheat protection.

E2: furnace surface overheating protection.

E3: under-voltage protection.

E4: High voltage protection.

E5: The synchronous detection signal is incorrect.

Troubleshooting after fault code:

E0: lm 358 is not good; Check the basic voltage of IC3; Poor welding of coil socket; Transistor Q5, Q 10 is broken.

E 1: check the fan circuit; IGBT temperature detection thermistor is damaged.

E2: The temperature sensor is broken; The resistance R 15 is poor.

E3: the power supply voltage is lower than165v; ; 7805 is not good; The transformer is broken.

E4: the supply voltage is higher than 255V;; Resistors R3, R4, R5 and R6 are bad.

E5: Resistors R52, R54, R55, R56 and R59 are bad; Transistors Q7, Q8 and Q9 are damaged.

Reproduction fault code table

Notes on serial number fault digital code

1 high and low voltage protection E 1

2 IGBT over-temperature protection E2

3 Furnace surface overtemperature protection E3

Kangbao induction cooker fault comparison table

70 degree lamp E 1 voltage is too high or too low.

100 degree lamp E2 pot bottom sensor open circuit short circuit.

140 degree lamp E3 IGBT sensor is open and short.

The current of lamp E4 is too large.

Nippon induction cooker fault code

E 1: no translation. The piccolo alarm goes off every 3 seconds. It will enter the standby state after continuous minutes.

E2: Power supply voltage is too low. Two long horns and three piccolo sounded the alarm. Ring the bell twice and turn to standby. (5 seconds apart).

E3: The power supply voltage is too high. Two long tones and four piccolo sounded the alarm. It rings every 5 seconds.

E4: Boiler overtemperature. Three sirens and three piccolo sounded the alarm. Ring the bell twice and turn to standby. (5 seconds apart).

E6: The pot is empty. Two long horns and three piccolo sounded the alarm. It rang twice and then went into standby. (5 seconds apart).

E0:IGBT is overheated. Four sirens and three piccolo sounded the alarm. Ring the bell twice and turn to standby. (5 seconds apart).

E7:TH open circuit (pipeline temperature sensor). Four sirens and five piccolo sounded the alarm. It rings every 5 seconds.

E8:TH short circuit (tube temperature sensor). Four sirens and four piccolo sounded the alarm. It rings every 5 seconds.

E9: The potentiometer sensor is open. Three long tones and five short flutes sounded the alarm. It rings every 5 seconds.

EE: The potentiometer sensor is short-circuited. Three long flutes and four short flutes sounded the alarm. It rings every 5 seconds.

VCE is too high. Silence. The retest begins.

Timed End: Turn to standby after a long tone.

There is no basic signal. The lights are off. Ring for two seconds and stop for two seconds. It is continuous.

Zi Long 1800d/E induction cooker fault display code is the same.

1. When the key of the induction cooker is short-circuited, the display shows E0.

2. When the main sensor of the induction cooker is turned on, the display screen shows E 1.

3. When the main sensor of the induction cooker is short-circuited, the display screen shows E2.

4. When the heat sink sensor of the induction cooker is turned on, the display screen shows E3.

5. When the sensor of the heat sink of the induction cooker is short-circuited, the display screen shows E4.

6. When the working voltage of the induction cooker is too low, the display screen displays E5.

7. When the working voltage of the induction cooker is too high, the display screen displays E6.

8. When the main sensor of the induction cooker is at high temperature, the display screen displays E7.

Common fault codes of induction cooker in Le Bang

Fault symptom fault display code fault reason

When the LED flashes and the buzzer sounds, the E0 circuit fails.

LED flashing, buzzer short circuit E 1 No cooker, wrong cooker.

The LED flashes and the buzzer rings for a long time. The IGBT is overheated.

LED flashes, buzzer is short-circuited, E3 voltage is too high.

LED flashes, buzzer is short-circuited, and E4 voltage is too low.

The LED flashes and the buzzer buzzes. E5 sensor short circuit/open circuit.

The LED flashes and the buzzer rings for a long time. The bottom of E6 pan is overheated.

Le Bang induction cooker fault code

E 1。 No marijuana

E2。 The IGBT is overheated.

E3。 High voltage.

E4。 Lower voltage limit.

The E5 sensor is open.

E6。 Guo di gan Shao

Le Bang induction cooker maintenance

First, the fault code

First, the fault symptoms. Fault display code III. failure cause

Four. The led flashes and the buzzer rings. There is something wrong with the circuit.

Seven. The LED flashes and the buzzer rings. Eight. E 1 IX。 Without a pot, the pot is wrong.

X. the X.LED flashes and the buzzer rings XI. E2, twelve. IGBT overtemperature.

Thirteen. The LED flashes and the buzzer is short XIV. E3 XV. Overpressure.

Sixteen. The LED flashes and the buzzer is short-circuited XVII. E4 XVIII. Low voltage.

Nineteen. The LED flashes and the buzzer sounds XX. E5 XXI。 Sensor short circuit/open circuit.

Twenty-two The LED flashes and the buzzer rings. E6 twenty-four. The bottom of the pot is overheated.

Second, the common troubleshooting process

1, several common maintenance methods

(1) Visual inspection method: A method to determine the fault by first checking whether there are burnt or damaged parts.

(2) Contrast method: the method of judging the failure by replacing the suspected parts of the induction cooker with the same parts.

(3) Division method: the method of dividing the induction cooker into several parts to determine the fault.

Mike electromagnetic oven fault code

E0 has no pot.

E 1 under-voltage protection

E2 high voltage protection

E3 furnace surface sensor short circuit

E4 furnace surface sensor is open.

E5 furnace temperature is too high.

The E6IGBT sensor is open.

E7 line fault or software fault (fast beep)

Midland induction cooker automatic protection error screen display code:

E-0 input voltage is too low]

E- 1 input voltage is too high.

E-2 IGBT temperature sensor open circuit or low temperature protection

Short circuit or high temperature protection of E-3 IGBT temperature sensor

E-4 stove surface temperature sensor open circuit or low temperature protection.

E-5 oven surface temperature sensor short circuit or high temperature protection]

Automatic shutdown: in-machine over-temperature protection.

Comparison table of Midea's electromagnetic oven SF164/174/184/194/204/214.

E0 1 open circuit (main sensor is damaged)

E02 short circuit (main sensor damaged)

E03 High temperature (main sensor damaged)

E04 open circuit (bad radiator sensor)

E05 short circuit (bad radiator sensor)

E06 High temperature (bad radiator sensor)

E07 under-voltage protection

E08 high voltage protection

E 10 dry-burning protection

E 1 1 The main sensor is broken.

Midea's induction cooker EP181ep201

Fire light 1 main sensor is open.

Fire Lamp 2 Main Sensor Short Circuit

Firelight 1 2 main sensor high temperature

Fire light 3 radiator sensor is open.

The heat sink sensor of fire lamp 1 and 3 is short-circuited.

No.2 and No.3 fire lights radiator sensor temperature is high.

Firelight 1, 2,3 voltage protection

Firelight 4 high voltage protection

Dry burning protection of Firelight 2 and 4 pots

Sensor fault protection of Firelight 1, 2 and 4

Midea induction cooker 07 new episode

EP 199/ 176/ 186/ 196/206

Fire lamp 2. 3 high temperature in the scintillation furnace.

Firelight 1. 4 flashing fire lights 2. 4 Flash ceramic plate high temperature

Firelight 1. 2.3 Flash fire lamp 4 Flash voltage level.

Firelight 1 sensor

Firelight 2 sensor

Firelight 3 sensor

Firelight 1.3 sensor

Firelight 1.2.4 sensor

Midea induction cooker 07 new episode

sh 1720/ 1820/ 1920/2020/2 120/2220

E6 furnace high temperature

E3 E 10 EA ceramic plate is resistant to high temperature.

E1e2e4e5e11EB sensor

Midea induction cooker

Fire light 1 main sensor is open.

Fire Lamp 2 Main Sensor Short Circuit

Firelight 1 2 main sensor high temperature

Fire light 3 radiator sensor is open.

The heat sink sensor of fire lamp 1 and 3 is short-circuited.

No.2 and No.3 fire lights radiator sensor temperature is high.

Firelight 1, 2,3 voltage protection

Firelight 4 high voltage protection

Dry burning protection of Firelight 2 and 4 pots

Sensor fault protection of Firelight 1, 2 and 4

Midea induction cooker fault code

E0: No pot.

E 1: low voltage

E2: High voltage

E3: High furnace surface temperature

E4: Open circuit of furnace surface temperature sensor

E5: IGBT temperature is too high or IGBT temperature sensor is open.

E6: IGBT temperature sensor is open.

E7: Excessive current

Midea SY 19 1

Fault code code meaning

E 1 main thermostat thermistor is open.

E2 main thermostat thermistor short circuit

E3 main thermostat thermistor high temperature

The thermistor of E4 IGBT tube is open.

The thermistor of E5 IGBT tube is short-circuited.

E6 IGBT tube thermistor high temperature

E7 under-voltage protection

E8 high voltage protection

EA dry burning protection

Failure of thermistor in ed ·IGBT tube.

E0 can't detect the pot.

Meierya induction cooker

E2 temperature sensor fault.

E3 Overvoltage 260V

E4 undervoltage 170V

E5 furnace surface overtemperature, treatment method, waiting for cooling.

E 1, the temperature inside the machine is too high. 2. The air outlet is blocked, 3. There is something wrong with the fan.

Nanning Li Duo induction cooker

E0- Current is too high .. 70 degrees light flashes.

E 1- The voltage is too low .. 100 degree light is flashing.

E2- voltage is too high .. 140 degree light is flashing.

E3-IGBT sensor is open or short-circuited ... 200-degree light flashes.

E4- Current signal zero-crossing detection, 270-degree light flashing.

E5- The furnace surface sensor is open or short-circuited ... The chafing dish lamp is flashing.

E6- Over-temperature protection caused by dry burning of furnace surface. The heat preservation light is flashing.