Gas-fired wall-hung boiler is a very common heating equipment, especially in the northern region. It is very important to prepare a good gas-fired wall-hung boiler before winter comes. The following is how to turn on the gas wall-hung boiler.

step 1: check the gas supply

before turning on the gas wall-hung boiler, it is necessary to ensure the safety and normality of the gas supply pipeline. Open the valve of the gas pipeline and listen to the sound of gas flowing into the burner. If the gas flow rate is too fast or too slow, it is necessary to adjust the gas valve. At the same time, before opening the gas wall-hung boiler, you can use the air pump to test whether the gas supply is normal.

step 2: prepare to start the gas wall-hung boiler

before preparing to start the gas wall-hung boiler, it is necessary to ensure that all components of the gas wall-hung boiler are intact. Check whether the gas pipeline is closely connected to the power supply, check the exhaust system, or simply check the electrical wiring of the wall-hung boiler.

Step 3: Start the gas-fired wall-hung boiler

Start the gas-fired wall-hung boiler according to the following steps:

1. Turn the home thermostat to the temperature state (if any).

2. turn on the power switch of the gas wall-hung boiler.

3. turn on the gas switch, which is often beside the switch, and it is crucial to turn it on in one direction and turn it on in the opposite direction. When turning on the gas switch, you need to hear the igniter start and enter the ignition state. If there is no ignition, it is necessary to check whether there is any problem with the igniter and gas pipeline.

4. when the wall-hung boiler starts to ignite, you need to wait for a moment until the wall-hung boiler is fully started. At this time, we need to pay attention to the control panel of the gas wall-hung boiler to ensure that there is no fault in the gas wall-hung boiler.

step 4: check the working state of the gas wall-hung boiler

after starting the wall-hung boiler, it is necessary to check the working state of the gas wall-hung boiler. If the gas wall-hung boiler has a display screen, it is necessary to check whether the gas wall-hung boiler works normally. If the gas wall-hung boiler is found to be out of order, it should be closed immediately.

Summary

The above is the method of opening the gas wall-hung boiler. It should be noted that before opening the gas wall-hung boiler, the gas pipeline and electric circuit should be inspected. In addition, in the process of using gas wall-hung boiler, we need to pay attention to other problems such as troubleshooting of gas wall-hung boiler. If you have any other questions about the use process of gas wall-hung boiler, please consult a professional.