1. Online filing: Fill in the form and declare it on the fire control network, and send the information to the fire control department for inspection within 5 working days if it is selected;
1, online application for approval; The compilation of all relevant design data, decoration design drawings, fire water supply, automatic fire extinguishing system, automatic fire alarm system, fire power supply system, smoke control system, emergency lighting and evacuation indication system and other relevant fire protection system design drawings shall be designed by formal qualification units and sealed documents shall be provided; At the same time, provide business license and qualification certificate; Obtain the decoration permission letter issued by the fire department;
2. Online application for approval is not selected: direct construction must be accepted (the information selected in online application must be perfect before it can be accepted);
Second, the decoration permit; Obtain the decoration permission letter issued by the fire department; Third, send for inspection; 1, material samples, building materials used in the process of fire protection decoration, take samples for inspection; Generally, the most frequently sampled fire-fighting coatings, fire doors, emergency lights, evacuation signs, fire extinguishers, and carpets are also decorated.
2. Preparation of materials and materials, copies of relevant qualification certificates of sample materials, inspection reports submitted by legal inspection institutions of fire protection products, and production licenses or filing certificates of fire protection products sold and used in our province;
3. Prepare enterprise information;
Fourth, acceptance; After the completion of the fire fighting project, you should apply for acceptance; There are two options for online declaration by lottery:
1, the fire department staff came to the site for acceptance; According to the actual situation, on-site acceptance is not required, and it is decided according to the particularity of the project;
2. If the acceptance is unsuccessful, all the above-mentioned relevant fire protection design materials must be provided, and the pictures and texts are consistent with the actual construction; 5. Unpacking inspection; The fire brigade will send staff to the site to check whether it is consistent with the information you submitted and whether it meets the specifications. You can't start business until you get a certificate;
6. on-the-job training; The staff went to the door to preach fire protection knowledge, explain the use of fire equipment, the implementation plan of emergency rescue drills for fire accidents such as escape, popularize relevant fire protection knowledge, master emergency rescue procedures and the operation and use of fire equipment, and improve the emergency handling ability of on-site management personnel.