If the number of foreign experts is less than 15, in principle, foreign recruitment will not be done alone, and the construction unit will make appropriate arrangements according to the specific circumstances. Article 4 If it is really necessary to build new outsourcing, it should be built in the factory area in principle, so as to facilitate the centralized management of the construction unit, and * * * use water, electricity and steam sources to save auxiliary area. Fifth, the construction of external recruitment should be based on the current use demand; At the same time, it is necessary to consider the long-term use direction of experts after they leave China, improve the utilization rate of foreign recruitment, and give play to the investment benefit, but we must never expand the construction scale and improve the construction standards on the pretext of considering the future use demand. Chapter II Construction Scale Article 6 According to the number and needs of foreign experts received during the construction period, the scale of foreign recruitment shall be considered as a whole. The total number of beds is determined according to the peak number of people coming to China by stages (including the family members stipulated in the contract) and the allowance of 10%. Seventh comprehensive construction area per bed index control in 50-60 square meters (60 square meters below 50 beds, 50 square meters above 200 beds). If the contract stipulates that some rooms can be used by two people, the area index is lower. Chapter III Indicators of Construction Land Article 8 For buildings with five floors or less, the land use coefficient (the ratio of the total area of existing buildings to the land use area) should be around 0.8; Multi-storey buildings with elevators should reach 1.5 or above. All of them include small activity places and green spaces set up in the outside recruitment hospital; Chapter IV Guest Rooms and Public Service Facilities Article 9 Guest Room Standards
1. Expert housing is considered as one person and one room in principle. But the possibility of leaving extra beds. The single room covers an area of about 20 square meters, including wardrobe, bathroom and indoor aisle. The residential area is about 14 square meter.
2. The number of rooms in the double suite is set according to the proportion of family members agreed in the contract.
3. If the contract requires a small number of three suites, a flexible combination of unit rooms and double suites will be adopted.
4. If the contract requires you to cook by yourself, you can set up several kitchens appropriately.
The height of the living room should not exceed 3 meters. If air conditioning is used indoors, the height can be reduced appropriately. Article 10 Public and service facilities
1. According to the living and working habits of experts and considering the rationality of long-term use, rooms for small meetings, meeting guests, reading, entertainment, retail, hairdressing, medical care, posts and telecommunications can be set up.
2 warehouses, computer rooms, laundry rooms, internal offices, workers on duty and other auxiliary rooms should be saved as much as possible.
The area of kitchen and dining room should be considered according to the number of people who receive meals at peak hours and the number of people who accompany us to the banquet.
4. Garage and surrounding facilities should make full use of the existing buildings and facilities of the factory.
5. Multifunctional use of public areas should be considered as much as possible. Chapter V Equipment Standards Article 11 Cold and hot water systems and heating and refrigeration facilities shall be set up.
Heating and cooling methods should be determined according to local conditions. Twelfth buildings with more than 5 floors can be equipped with elevators. Thirteenth rooms and bathrooms are equipped with toilets, washbasins and bathing equipment. Fourteenth furniture and equipment shall be subject to the application, and the supply of goods shall be solved locally and nearby.
The TV antenna and electrical socket should be reserved in the guest room, and the electrical load margin should be properly considered. Chapter VI Decoration Article 15 Decoration shall be economical and beautiful, and high-grade decoration shall not be adopted. According to local conditions, try to use local building materials. Chapter VII Supplementary Provisions Article 16 These Provisions may also be applied to the construction of external recruitment by the departments of education, health and foreign trade. Seventeenth localities and departments can formulate specific implementation measures within the scope of the indicators determined in the Regulations. And send a copy to our standard quota bureau. Article 18 These Provisions shall be implemented from 1986+ 10/0/day. 1978 Several Opinions on Building Standards for Hostels for Foreign Technicians issued by the former State Construction Committee shall be abolished at the same time.