Current location - Recipe Complete Network - Catering training - Decision of Xi People's Government on Amending the Provisions on the Management and Hygiene Supervision of Secondary Water Supply in Xi (2020)
Decision of Xi People's Government on Amending the Provisions on the Management and Hygiene Supervision of Secondary Water Supply in Xi (2020)
1. Paragraph 2 of Article 2 is amended as: "The secondary water supply facilities mentioned in these Provisions refer to pump houses, pools (tanks), pipelines, valves, water pump units, disinfection equipment, pressure water containers and other facilities. Used for secondary water supply. " Two, fourth is amended as "the municipal water administrative department is the administrative department in charge of secondary water supply management in this Municipality, and its subordinate secondary water supply management institutions are specifically responsible for the supervision and management of secondary water supply in this Municipality. The administrative department of health is the administrative department in charge of the hygiene supervision of secondary water supply in this Municipality, and is responsible for the hygiene supervision of secondary water supply.

The water administrative departments of yanliang district, Lintong, Chang 'an, Gaoling, Hu Yi, Lantian and zhouzhi county are responsible for the supervision and management of secondary water supply within their respective jurisdictions.

Housing construction, resource planning, fire protection, market supervision, public security and other departments shall, in accordance with their respective responsibilities, cooperate in the management and supervision of secondary water supply. Three. One article is added as revised Article 5: "Secondary water supply shall adopt technologies and equipment that are safe, reliable, hygienic, environmentally friendly, energy-saving and water-saving, and implement intelligent management.

Secondary water supply management institutions should do a good job in the selection of energy-saving and environmental protection equipment and materials for secondary water supply and the publicity and training of secondary water supply industry. Four. Article 6 is amended as Article 7, which reads: "The design scheme of newly built, rebuilt and expanded secondary water supply facilities shall meet the basic conditions and management requirements for connection with urban public water supply networks. The design and construction of secondary water supply facilities shall implement the relevant standards of the state, province and this Municipality. " 5. Article 7 is renumbered as Article 8 and amended as: "The design and construction of secondary water supply facilities must meet the following requirements:

(a) pool (box) volume and pipe diameter should meet the requirements of water;

(two) the top of the reservoir and the surrounding drainage is smooth, and the top of the reservoir must be provided with the necessary number of air holes;

(3) The pool wall is firm, flat and leak-proof, the pool (box) cover should have good sealing performance, and the vent hole has a device to prevent mosquitoes and foreign objects from entering the pool;

(four) the secondary water supply pump room should be set up separately, and it should not be mixed with the fire pump room. The pump room should have an independent electricity metering device that can be settled by trade. The water storage tank should be built separately from the fire pool for cleaning and maintenance.

(five) secondary water supply and storage facilities should be set up separately, and equipped with devices to prevent water pollution;

(six) residential and non-residential buildings in the same building shall be provided with secondary water supply facilities respectively;

(seven) within 30 meters around the secondary water supply facilities, it is forbidden to pile up toxic, harmful and perishable substances, and it is forbidden to set up pollution sources such as seepage toilets, seepage pits, cesspits and garbage dumps;

(eight) water storage, water distribution, water delivery, overflow and other facilities shall not be directly connected with drainage facilities;

(nine) building materials, pipeline valves meet the hygiene and quality requirements;

(ten) supporting the construction of monitoring systems, intrusion alarm systems and other security technology prevention systems, setting up anti-theft doors and windows, locking plates and cover plates, protective nets and other physical defense facilities to prevent malicious damage, and implementing closed management;

(eleven) the water pump unit is operating normally;

(twelve) other requirements stipulated by laws and regulations. Article 9 of the intransitive verb is revised as Article 10, and the second paragraph is revised as follows: "After the completion of the secondary water supply facilities, the construction unit shall organize the acceptance, and notify the water administrative department and the health administrative department to participate in the acceptance. Without acceptance or unqualified acceptance, it shall not be put into use. " One article is added as revised Article 11: "The secondary water supply facilities shall be managed and maintained by their property owners or the units entrusted by them." 8. Article 12 is revised as Article 14, which is amended as: "The cleaning of secondary water supply facilities shall be managed by the municipal water administrative department in a unified way, and the cleaning announcement system shall be implemented, and the secondary water supply units shall choose their own professional cleaning units established according to law. Professional cleaning units should sign cleaning contracts with users and publicize relevant information before cleaning. " 9. Article 13 is amended as Article 15, which reads: "The secondary water supply unit shall clean and disinfect the water supply facilities at least once every six months, and entrust a qualified unit to carry out water quality testing to ensure that the water quality of the secondary water supply meets the national standards, and can only be used after passing the testing.

Two water supply units shall publish the results of water quality testing. 10. Article 16 is changed to Article 18 and amended as: "Professional cleaning units engaged in secondary water supply cleaning must implement the following provisions:

(a) the establishment of the user's secondary water supply facilities cleaning data files, do a good job in tracking services;

(two) after each cleaning and disinfection, it shall entrust a qualified water quality inspection department to take water samples for inspection;

(three) after receiving the second water pollution report of the users who have signed the cleaning contract, they should immediately report to the municipal water administrative department and the health administrative department, and send someone to deal with it within 24 hours;

(four) accept the supervision and inspection of the water administrative department on the cleaning and disinfection of the two water supply facilities. "Eleven, delete seventeenth. Twelve, eighteenth as the revised nineteenth, and one of the "health and family planning administrative departments" to "local health administrative departments".