Accumulator setting screen: When the accumulator initial setting page is displayed, the clear key is displayed. (Dele
Accumulator setting screen: When the accumulator initial setting page is displayed, the clear key is displayed. (Delete key changed to Clear key)
Tool clearance
Using this parameter, set the core moving target position (tool off) through the [Tool] switch located in the following two positions. Set the range from 0 to 100% (the initial value is 0%) (for the definition of 0 to 100%, please refer to.
)
F4: Monitor screen: The tool switch can be pressed in manual mode. ..
Accumulator setting screen: When the accumulator initial setting page is displayed, the tool key ... (the shift key becomes the tool key) will be displayed.
Purge/tool is the core forced opening and closing function. This function is effective when replacing resin or performing the initial setting (zero range) of accumulator.
The speed at which the cleaning/machining switch moves the core is the speed set by the "Chip Gap Slope".
Please refer to section.
Accumulator setting for cleaning/machining function during accumulator setting.
Timing device
Time setting for executing internal timer.
Set the time on this screen when the initial state does not have the correct time or power on for a long time.
date
Enter a date.
time
The time is set.
set up
After entering the date and time, the set will set a timer and start counting.
2-4-4.F3: File Mode
Press F3 to enter the mode.
show
Available when manufacturing containers.
function
This mode combines configuration files, tag data and setting files and stores them in flash memory or USB memory for future use. Flash memory can store 100 files, and SD card can store data, depending on the size of USB memory. The stored data has an identification name, date and time of up to 32 characters.
order
When F3: file mode is selected, the options of loading, loading USB, saving or saving USB will be displayed (
). You can use the cursor to select load, load USB, save or save USB, and set or directly touch the applicable items.
Figure 2-20 File Mode Selection Screen
Save or save USB
Save or save USB Combines configuration file data, function item data and point marks into one file, and stores the file in flash memory or USB memory.
Use the up/down cursor to select Save or Save USB, and then press the Set key or touch them directly. (
)
The prompt "Please edit the file name Yes/No" will be displayed. (
)
If you choose Yes, go to page 63. If you choose No, please go to page 62.
Figure 2-2 1 Select Save
If you choose No, please follow the instructions below. ..
Liquid crystal display (
) displays the description of the file data, and press SET at Next to view each display one by one.
To save the file, use the rotary knob to move the cursor to "Save" and press the setting key or directly touch "Save".
If you choose "Save", DigiPack will save the data in the flash RAM (or in the USB memory if you choose to save USB) and display the saved data in Profile mode. (F 1: personal data).
If "Exit" is selected, the first screen of F3 file mode will be displayed without saving any data.
Figure 2-22 File Description Data-Page 1
Figure 2-23 File Description Data-Page 2
Figure 2-24 File Description Data-Page 3
If you choose "Yes", please follow the following instructions …
The LCD screen switches to the editing screen (
) and prompt "file name". Use the rotary knob or direct touch to enter the file name (maximum 32 characters). Turning the knob moves the display cursor from one character to another. SET key Enter a single character of the file name.
special character
The "←" and "→" symbols are used to move the display cursor within the file name.
The last character in the list inserts a space in the name.
The "end" character is required for the entry to be completed. You must insert "END" at the end of editing, otherwise the new file will not be renamed. (If you haven't changed the name, please skip to.
)
The LCD screen changes to the file number selection screen (
) and prompt "file number". Use the rotary knob (in increments of 1) and the cursor keys (in increments of 20) to move to the required document number. Press SET to enter. Or touch the designated number box, specify the required file number, and then press [Settings].
After selecting the file number, the LCD screen will display the description of the input data (
) and displays the "Exit or Save or Next" prompt. If "Save" is selected, DigiPack will save the data and display the file name in F 1 Profile mode. If you choose "Exit", you will return to the first screen in F3 file mode without saving any data.
If another data has been stored in the location with the specified file number, it will be saved in that location. In this case, the previously saved data will be lost.
Figure 2-25 Edit File Name
Figure 2-26 Change the file number
If you select "load or load USB" (
). Displays a list of files, starting with "Initial File No.0" (
!