I. Principles
The principle of electromagnetic valve of gas stove is to control the opening and closing of the valve through the action of electromagnet. When the electromagnet is energized, it will generate a magnetic field, and under the action of the magnetic field, the valve will open or close. In the gas stove, the solenoid valve controls the flame size by controlling the inlet and outlet of the gas.
Second, the structure
The electromagnetic valve of gas stove is simple in structure and mainly consists of electromagnet, valve and connecting pipe. Among them, the electromagnet is the core component to control the valve switch, the valve is the component to control the gas in and out, and the connecting pipe is the component to guide the gas to the burner.
Third, application
Solenoid valves for gas stoves are widely used in gas stoves of families and enterprises. When using the gas stove, we need to operate the solenoid valve according to the following steps:
1. Turn on the switch of the gas cooker and let the gas enter the gas cooker.
2. Press the ignition switch of the gas stove to ignite the gas.
3. Adjusting the flame size of the gas stove can be realized by rotating the knob on the gas stove.
4. After using the gas stove, the switch of the gas stove must be turned off to prevent the gas from entering the gas stove.