Current location - Recipe Complete Network - Diet recipes - Operating instructions for remote control of weighbridge
Operating instructions for remote control of weighbridge
First, product installation

Open the box and take out the weighbridge remote control host, antenna, power adapter, etc.

Installation of antennas: Install antennas in turn, remember not to disturb the order, and make sure that each antenna is screwed to the end. Just put the instrument in a proper position.

Boot: plug in the power adapter, turn on the power switch, and the instrument will start self-checking and display startup information.

Second, set up automatic shielding

By default, the instrument host only detects illegal signals after starting, and does not actively shield them. If you want to set the instrument to automatically shield after detecting illegal signals, you need to turn on this function. The equipment will form a radio safety protection area around the weighbridge as follows:

1, tap the "AUTO" button in the shortcut key area, and the "Auto Mask" indicator on the right side will always be on, and the word "Auto" will be displayed at the top left of the screen, which means that the auto mask function has been turned on;

2. If you need to turn off the automatic shielding, press the "Automatic" button lightly, and the automatic shielding will be turned off, and the indicator light will not light up.

Three, manually open and close the shielding function

In automatic mode, if the host detects an illegal signal, it will automatically shield the illegal signal, accompanied by a voice prompt. If it is necessary to manually shield the weighbridge from illegal signals by remote control, the setting method is as follows:

1, press the "Shield" button for three seconds to enter the shielding state, the word "SH" will be displayed at the top of the screen, and a voice prompt will be issued at the same time. In this state, all illegal information will be intercepted and shielded;

2. If you need to turn off the voice prompt in the shielded state, just press the "Mute" button.

Fourth, set to silent shielding mode.

Turn on the automatic shielding function, and then press the "Mute" key lightly to set the instrument to silent shielding mode. At this time, if an illegal signal is detected, no voice alarm will be given, but only recorded and shielded.

V. Query function

1, access method: select the "query key" in the shortcut key area on the weighbridge remote control host or select the "query" menu on the screen to access.

2. Enter the administrator password.

3, select the remote control code query

A) Select the month to be queried and press the "Set" key.

B) illegal cheating signals monitored in the last three months will be displayed on the screen, including date, time, code value, cheating frequency, resistance, chip, cheating times and other information.

C) If you want to delete cheating records, select the month to delete, and press the down arrow key in the direction key area for three seconds, and all the records of the month will be deleted.

4, select the switch query

A) Select "On/Off Inquiry" to enter, and you can see the on/off time record of the instrument host in the last three months. Normal shutdown or illegal power failure will be automatically recorded for the administrator to check.

B) Delete on-off records: select the specified month in this interface, and press the down arrow in the direction key area for three seconds to delete all on-off records of this month.

Sixth, verify the illegal cheating signal

The anti-remote verification function of the weighbridge has the key verification function while recording the cheating tonnage of the cheater, and each key tonnage set by the illegal cheater can be restored on the instrument, so that the possible maximum loss of the enterprise can be calculated.

The method is as follows:

1, press the "Query" button and enter the administrator password;

2. Select "Remote Control Code Query"

3. Find the records to be verified in the existing cheating information;

A) Press the "original code" key to restore the cheater's latest cheating tonnage to the instrument;

B) Press "1 key", "2 key" … "8 key" below to restore the cheating tonnage of cheaters for each key respectively.

Seven, modify the administrator password

1, select "clock" or "query" menu to enter.

2. Select "Modify Password"

3. Enter the original password and press the Enter key.

4. At the top of the screen, please enter a new password, enter a 6-digit new password and press the Enter key.

5. Password modified successfully 1: The digital weighbridge can prevent cheating; the digital weighbridge adopts digital weighing instruments and digital sensors, and its signal transmission adopts digital signal transmission. To cheat on digital scales, it is necessary to decipher the communication protocol, so the possibility of cheating on digital scales is very small.

2. The video capture and weighing management system consists of computer, printer, instrument, weighbridge software and camera. Enable the video capture function, and automatically capture the weighing scene when the data is saved during weighing. The scene of the vehicle on the weighbridge can be photographed, and the weighing time, weight, serial number, car number and other information can be automatically burned on the picture, and the dark blue fine print is extremely difficult to copy. You can also install three cameras, one of which is aimed at the weighbridge instrument, and the vehicle scene picture plus the instrument data picture is trinity to ensure foolproof. Both scales and pictures can match the query.