Vanke refined room inspection notes and details:
1, the roof height: take 4-5 points in the roof with a ruler to measure, if the value is the same, then the roof is not tilted.
2, the wall floor: use a long ruler and other close to the wall floor, check whether the wall is flat, while observing whether there are scratches and cracks, whether the wall is bursting point.
3, the quality of the door: use a mirror to the top of the door and the bottom of the door, check whether these usually invisible places painted. Especially the bathroom door, if its top and bottom of the paint is not brushed all the way, over time, will make the bottom of the door premature rot damage. Check whether the security door has scratches, whether the edge of the door is deformed, whether the seal between the door and the frame is tight, whether the door and lock switch is flexible.
4, the quality of the door: use a mirror to the top of the door and the bottom of the door, check whether these usually invisible places painted. Especially the bathroom door, if its top and bottom of the paint is not brushed all the way, over time, will make the bottom of the door premature rot damage. Check whether the security door has scratches, whether the edge of the door is deformed, whether the seal between the door and the frame is tight, whether the door and lock switch is flexible.
5, windows: sliding windows on the screen and sash, should feel the push flexible, no collision with each other. Window outside the window frame should be anti-blocking cap, to prevent foreign body blockage affect drainage.
6, windows and doors sealing: check whether the sealing of windows and doors is good, a long strip of paper can be placed on the sealing point, close the door and press the strip of paper forcefully withdrawn, more than a few times the test can be seen sealing the pressure of the strip is uniform.
7, bathroom: A: bathroom in the hallway with windows should be installed security net. B: If there is no window, there should be ventilation holes. Ventilation holes in the ceiling below. The nearest socket to the ventilation hole shall be waterproof socket.
8, kitchen and bathroom: these two places are tiles to the top, to check the corners without bumping (roof corners and ground corners), floor tiles and wall tiles without deformation cracks and drums. With a small hammer scratching floor and wall tiles, there is a hollow sound, should be re-laid.
9, . Latex paint quality: when the surrounding light is dark, with a high-power light bulb (200 watts) irradiation, the light, the wall ceiling is flat will immediately be seen through the shadow of the light, if not flat, to re-fill the putty paint; if the local paint (repaired) will be different from the original color of the wall.
10, electrical inspection: the owners themselves can buy a professional electrical inspection, according to the instructions for use one by one acceptance.
11, hollow drum: the special steel needle hammer (10g) padded with a few layers of paper to knock the wall, check the wall hollow drum.
12, check the pipeline installation, smooth and sealed: with a strong hand to shake the heating pipe and the upper water pipe, should be fixed firmly. If loose, should be re-fixed. Open the water valve to see if the drainage is smooth, drain the water with toilet paper to wipe the bottom of the upper and lower pipes for leakage.
13, the heater: A: the heater should be above the vent, should be twisted when using the gas discharge. If unscrewed will need to be repaired to solve the problem, otherwise the gas can not be discharged, the heater is not hot.B: Also note that the heater installation of the inlet pipe and the slope of the return pipe to meet the requirements, otherwise it affects the heating.
14, the kitchen flue: with a paper roll ignition fire extinguish smoke, placed in the flue mouth below about 10 cm, to see if the smoke rises to the mouth of the flue immediately turn suction.
15, pipeline gas: with a smoldering roll of paper put near the alarm device to see if the device is sensitive; alarm sound and light prompted at the same time will close the inlet solenoid valve, if you can't, to repair in a timely manner.
I hope my answer can help you.