Xuebei commercial freezer is a kind of refrigeration equipment widely used in commercial places, catering enterprises, supermarkets and other fields. However, in the process of using the commercial freezer of Xuebei, it is inevitable to encounter some faults. The following are several possible faults and their solutions.
1. The temperature is too high or too low.
if the temperature of commercial freezer is too high or too low, it may affect the quality and safety of stored food. The reason for this problem may be that the compressor is damaged, there are too many items in the refrigerator or the temperature is set incorrectly. The solution is to reset the temperature, clean the contents and close the refrigerator door to minimize the heat dissipation time.
2. the noise is too high.
Commercial freezers will produce some noise during use, but if the noise is too loud or persistent, it needs to be considered. This problem may come from unbalanced operation, excessive dirt or damaged condenser or damping pad with too much water. You can try to readjust the radiator or clean it regularly and replace the damping pad.
3. Power supply problem.
The failure to turn on the commercial freezer may be caused by power problems, such as the plug connector not meeting the standard specifications, short circuit of the line, or the relay not working due to too long turn-on time. You can find electrical technicians to check electrical appliances and ensure safety.
4. water drops or frost stains.
some commercial freezers may accumulate frost stains or water droplets during the cooling process. this problem may be that the refrigerator door is not completely closed or the rubber sealing ring is worn. Ensuring that the door is well sealed and replacing the sealing ring can solve this problem.
5. other faults.
there are also some possible failures, such as water seepage and no refrigeration in the refrigerator. If this problem occurs, you can try to check whether the compressor, coolant helium and pipeline are unblocked, as well as electronic components and internal condensers. If it still can't be solved, you can seek the help of a professional maintenance company.
in a word, there may be many failures in the use of commercial freezers, but the failure rate can be reduced as much as possible through reasonable maintenance and the application of preventive measures.