1. First disconnect the power supply of the commercial freezer to ensure safety.
2. Determine the location of the starter to be replaced. Locate the starter according to the instructions of the manufacturer of commercial refrigerator. Usually, the starter is located above or on the side of the compressor, and the shell needs to be removed to operate.
3. Remove the shell and the old starter. Starter is divided into two parts: starting capacitor and starting electromagnet. First remove the capacitor, use the screwdriver above the notebook to remove the socket below the capacitor, and then pull out the capacitor. Then unplug the plug on the electromagnet cable with a screwdriver, and then remove the electromagnet.
4. Assemble a new starter. Insert the new capacitor into the socket and tighten it with a screwdriver; Connect a new electromagnet according to the plug connection method. After assembly, check whether the connection is correct and tight.
5. Reinstall the housing. After installing the starter, reinstall the housing of the commercial refrigerator. Finally, turn on the power and test whether the freezer is running normally.
In a word, the replacement of commercial refrigerator starter needs careful operation, pay attention to safety in the process, and follow the steps in the manufacturer's manual. If you need to install a new starter but have no relevant skills, it is recommended to ask professional maintenance personnel to operate it.