Six notes on the use and maintenance of disinfection cabinet
Disinfection cabinet is our daily disinfection assistant. But many people don't know how to use and maintain it after buying it. The following small series will help you explain.

How to use the disinfection cabinet:

1, tableware should be washed and drained before disinfection in the disinfection cabinet, which can shorten the disinfection time and reduce power consumption.

2. Tableware that can't withstand high temperature, such as plastic, can't be placed in the high-temperature disinfection cabinet below, but in the ozone disinfection low-temperature disinfection cabinet above, so as not to damage the tableware.

3, bowls, plates, cups and other tableware should be placed vertically on the shelf, it is best not to overlap, so as to ventilate and disinfect as soon as possible.

4. Pay attention to whether the ozone generator works normally. If you can't hear the squeak of high-voltage discharge and you can't see the blue light of discharge, it means that the ozone generator may have a fault and should be repaired in time.

5. Don't open the door unless necessary during disinfection, so as not to affect the disinfection efficiency.

6. After disinfection, it will be better to use it after 10 minutes. Open the cupboard door, and a small amount of ozone odor overflows. This concentration is harmless to human health. Please rest assured.

Precautions for maintenance of disinfection cabinet:

1, power on all the time: Although the sealing performance of the disinfection cupboard is good, if the infrared tube inside is not heated for a long time, it is difficult to exhaust the humid air in the cupboard in time, and the mold attached to the tableware will still breed and endanger human health. Therefore, don't put the tableware with water in the disinfection cabinet without frequent power supply, which will cause the electrical components and metal surfaces to be oxidized by moisture, and contact resistance will easily appear at the socket of the heating pipe, which will easily burn the socket or other components and shorten the service life of the disinfection cabinet.

2. To be "dry": the disinfection cabinet is heated and disinfected, and the temperature in the cabinet rises to 200 to 300 degrees Celsius through infrared heating pipes, thus achieving the purpose of disinfection. However, the electrode of the internal infrared heating pipe is easily oxidized due to moisture. Therefore, if water drops are put into the disinfection cabinet after tableware cleaning, the electrical appliances and metal parts in the cabinet are easy to be oxidized by moisture, lamps and other parts are easy to burn out, and the service life of the disinfection cabinet is easy to shorten.

3. Tableware materials should be selected: tableware that is not resistant to high temperature, such as plastic, should be placed directly in the ozone low-temperature disinfection box at the upper level of the disinfection cabinet, and tableware made of ceramics and glass should be placed at the lower level of the disinfection cabinet for high-temperature infrared disinfection. It should be noted that colored ceramics with colored glaze cannot be disinfected in a high-temperature disinfection cabinet, because heavy metals in colored glaze pigments, such as CNOOC lead and cadmium, are easy to overflow if they encounter high temperature, and these harmful substances are easy to decompose and pollute tableware under the mediation of high temperature.

4. scientific placement: the location of the disinfection cabinet is also very important. Generally, the distance from the wall is not less than 30cm. It is best to put it in a dry and ventilated place, and do not turn on the disinfection device, which will not affect the disinfection effect. It is best to take out the tableware after disinfection for a period of time, usually 10- 15min. Turn off the power supply or unplug the power supply in time after each disinfection.

5. Pour out the water in the water collecting tank at the lower end of the cabinet regularly and wipe it clean.

6. Ensure that the disinfection cabinet is electrified once a day, which can not only ensure the hygiene of the disinfection cabinet, but also prolong its service life. Turn it off when not in use.

Improper use of sterilizers will have adverse consequences, and poor maintenance will also shorten the service life. Therefore, it is very helpful for us to learn some of the above usage and maintenance skills.