1.4.2 class b boiler
(1) steam boiler, 0.8mpa ≤ p < 3.8mpa;
(2) hot water boiler, P < 3.8 MPa, t ≥120 c (t is the rated outlet water temperature, the same below);
(3) gas-phase organic heat carrier boiler, q > 0.7 MW (q is rated thermal power, the same below); Liquid phase organic heat carrier boiler, q > 4.2 MW.
1.4.3 C class boiler
(1) steam boiler, p≤0.8MPa, V > 50L (V is the designed normal water level, the same below);
(2) hot water boiler, 0.4 MPa
(3) Gas phase organic heat carrier boiler, q ≤ 0.7 MW; Liquid phase organic heat carrier boiler, Q≤4.2MW.
1.4.4 D boiler
(1) steam boiler, p≤0.8MPa, v ≤ 50l;
(2) hot water boiler, P≤0.4MPa, t≤95℃.
Note: 1-5: p is rated working pressure of boiler, rated steam pressure of steam boiler, rated outlet pressure of hot water boiler and rated outlet pressure of organic heat carrier boiler.