In today's society, there is no doubt that people have become more and more concerned about health issues, those water-injected beef, pork with lean meat extract, etc., have been plotting to harm our health, is that we are living everywhere in life, living insecurity. Drinking is also an important issue, the water environment is not as clear as it used to be. Even the mountain spring water that people now drink every day, are worried about the existence of parasites, so derived from the use of electric kettles, for electric kettles. I introduced the Rongshida electric kettle repair it, as a way to facilitate you.
No heating after power on, the indicator light does not light, how to do?
The failure is often due to the power supply did not join the electric heater circuit. Inspection and repair can first use the multimeter R × 10 gear to measure the base power cord on the 3-core plug L, N resistance at both ends.
Normal, did not press the reset switch resistance is ∞, press the button when the 1500W kettle corresponding to the resistance value of about 32Ω. If the resistance is still ∞ after pressing the button, indicating that the heating tube circuit does not work.
Then you can measure the kettle body 3-core plug N, L resistance at both ends, the normal value as above. If the measured results are normal, indicating that the fault is in the base part, should check the power cord and base socket connection is broken or poor contact, the base structure is simple, generally very quickly find the fault.
If the measured resistance is still ∞, indicating that the failure in the pot body circuit, should be disassembled handle cover components such as overhaul. Focus on the power (reset) switch and insulation switch. Available multimeter R × 1 gear to check the switch action and contacts on and off the situation is good.
If the action is found to be poor, you can check the temperature sensing piece of the tongue bending angle and the switch linkage position and so on whether it is normal, otherwise they should be corrected. If the switch action is normal and its contacts can not be connected, the switch reed or contact damage, you can disassemble the switch box clean maintenance.
If the power switch is normal, the fault occurs in the insulation switch
First look at the bimetallic reed is pressed against the switch lever (white plastic rod), if the pressure is too tight, available tweezers will be upward bending until the two spacing of 0.5 ~ 1mm so far. If the spacing between the bimetal and the switch contact bar is normal, the switch box should be disassembled to clean and repair the contacts and reeds of the insulation switch.
No heating after power on, but the indicator light is on, where is the problem?
Indicator light, that the power supply has been added to the indicator circuit, the fault in the heater or its connection part, common heater damage and poor contact. Remove the heater to measure its resistance can be judged.
The heater is damaged and can only be replaced. Poor contact is mainly due to the power plug assembly in the contact reed serious corrosion or deformation, can be removed from the switch box cleaning maintenance, serious damage to the best new.
How to solve the problem of uninterrupted power supply after boiling water?
Mainly due to the failure of the reset switch. Common causes are serious deformation of the temperature sensing piece or switch linkage action is blocked.
For the former, you can re-bend the temperature sensing piece of the tongue of the protruding angle, so that it pushes the action of the switch linkage is normal. The latter need to find out the blocked parts or foreign objects, generally as long as the removal of foreign objects and correct the position will be able to return to normal.
What is the solution to the problem of dry boiling without breaking the power?
The kettle water boiling dry or empty kettle power for a period of time does not automatically cut off, mostly due to the failure of the insulation switch. Can check whether the bimetallic sheet deformation or loose. If the deformation, the use of sharp-nosed pliers to recalibrate, bimetal and switch contact bar spacing should be 0.5 ~ 1mm. If loose, just tighten the set screws can be.
How to solve the slow heating speed?
The common reason is that the power supply voltage is too low, the indoor power line or plug seat contact is poor, should be excluded first. Then check whether the electric heater is serious accumulation of dirt, the base and the pot body of the power plug seat contact between the serious bad, etc..
If the electric heating tube accumulates dirt, you can first use a knife to gently scrape, and then use fine sandpaper to polish. If the base and the pot body of the power plug seat between the contact is seriously bad, you can first remove the plug seat contact piece and contact oxidation layer, dirt, and then correct its shape, so that the two contact tight and good.
Correct use and maintenance of electric hot water bottles
Electric hot water bottles are very popular due to their ease of use and convenience, the general family are in use, but do you master the correct way to use it? Do you maintain it properly? Read our article, hope you can get a little inspiration.
The use of electric kettle points
1. electric kettle bought back, to carefully read the manual, understand its maximum power to configure the corresponding plug board, and try to use in the children's place is not easy to touch, so as to avoid burns.
2. Check the switch of the electric kettle, make sure that the switch of the power supply is in the off position before energizing, so as to avoid the impact of the current damage to the body, affecting the service life.
3. When adding water, read the water level line prompts, and be careful not to exceed the maximum water level line to avoid damage.
4. electric kettle in the operation of boiling water, pay special attention to, must be supervised, so as to avoid overflow of boiling water, the body of the short-circuit caused by the safety hazards, and placed in the position of the child can not touch, to ensure safety.
5. electric kettle boiling water may wait for a period of time, need to be patient, can not uncover the lid, so as to avoid the emergence of water vapor scalded face or hands, resulting in Shanghai.
6. When the kettle will boil the water, please unplug the power supply in time, or make sure that the kettle switch is in the off position, to prevent the chassis from overheating, resulting in danger.
7. When the kettle is in operation, it will generate heat energy, the body becomes hot is very normal, so in the grasp, can only hold the handle, or the other hand with a wet towel to assist, do not touch directly.
8. Need to remind the point is that the function of the electric kettle is only used to boil water, can not be used to cook other things, and if there is no water in the kettle, do not dry burning, so as not to cause danger.
The hot water bottle should be placed flat. In order to avoid uneven heat. At the same time, because the general electric hot water bottle is used in the plastic shell, so do not place the stove and other heat sources and a variety of flammable gases near, or light is baked surface, affecting the aesthetic. Heavy may make the hot water bottle useless.
Small introduction of so much information, I hope to help you to Rongshida electric kettle as soon as possible to repair. Rongshida electric kettle is now one of the brands of hot water kettle in use by the general public, bringing everyone technologically advanced, as well as physical health protection. The electric kettle as an important tool for everyone's daily drinking water, with a temperature of 100 degrees when the water boiling, as well as the bacterial body of the enzyme inactivation, and then the death of bacteria, for everyone to produce pure drinking water, to protect the health of everyone from infringement.