Solution of air conditioning air outlet condensation:
1, air vent condensation is generally too much humidity indoors, you can appropriately increase the temperature of the air supply, just turn on the air, can be set to 26 ° - 28 °, and then after a period of time to adjust to the temperature they want. Adjust the air speed of the indoor unit.
2, air-conditioned room doors and windows to pay attention to tightly closed, do not let the outdoor hot and humid air penetrate into the air-conditioned room. As the air conditioner itself with a certain dehumidification capacity, with the operation of the air conditioning, the humidity in the air in the room will gradually reduce, condensation will gradually less, until no longer dew.
3, in addition, you can adjust the angle of the outlet blades, so that the exit to produce large turbulence, increase the edge of the part of the induced wind, to solve the above problem will also be helpful.
Extended informationAir conditioner outlet drip is a normal phenomenon, it shows that your home air conditioning is running well, and cause air conditioning outlet dripping reason section may be the following reasons:
1, summer hot areas of the room when the humidity is higher, the dew point temperature of the air is higher, when the temperature of the air supply is lower than the dew point temperature of the air in the room, air conditioning out of the air louvre air outlet will be condensation It is a normal phenomenon that condensation drips, especially in the period of time when the air is just turned on. Therefore, condensation on the air conditioning outlet is not a quality problem, on the contrary, it shows that your home air conditioning cooling effect is very good.
The most obvious example is in the summer, just out of the refrigerator soda, the surface temperature and the ambient temperature difference is too large, the water vapor in the air immediately in the ice drinks on the outer packaging to form dew.
2, the central air conditioning installation is not in place
If the central air conditioning in the installation is not in place, so that the vent four-wall connection is not flat, not sealing caused by the phenomenon of dripping, but also prone to a series of other problems.
3, poor drainage
Drainage due to the aging of the drainage pipe slack or bent into a wave shape, resulting in poor drainage. Or, the drain pipe leading out of the outdoor area is artificially blocked or the drain is blocked by stolen goods, resulting in dew water can not be discharged.