Maintenance steps of Jiuyang soybean milk non-running machine:
1. If there is no response after the soymilk machine is powered on, we should first check the power cord to see if there is any problem. We can take the machine apart and measure it with a multimeter to see if there is a short circuit or an open circuit. If it is well connected, we can rule out the power cord problem.
2. Measure the fuse tube of the circuit board with a meter (the component covered with a black sleeve on the board) to see if there is a fuse phenomenon. If there is a fuse, it means that there are traces of fire in the plastic part of the machine. This is caused by the burning of the circuit and the spark from the internal combustion of the motor.
3. Next, we need to remove the motor and look at the degree of internal damage. If the circuit board is damaged in a large area and the motor is burned, it should be caused by water entering the nose when it is not cleaned properly.
4. In this case, the maintenance is very complicated. Only by replacing the main engine and motor can the soymilk machine return to normal operation. The back of the main board is full of small patch components and chips, which is relatively more time-consuming and labor-intensive. Therefore, the soymilk machine must not be placed directly under the faucet for cleaning, which is very likely to cause damage to the internal circuit due to water ingress.
How to maintain Jiuyang soymilk machine;
1, Jiuyang soymilk machine should operate according to the corresponding functions when pressing the keys, otherwise the soymilk produced will not meet your requirements. When the soymilk machine is in operation, you must remember to install the Lafar net to prevent the soymilk from overflowing and scalding. Please don't unplug or plug the power cord immediately in the later stage of the machine's work, and wait until a long alarm sounds to show that the work has been completed, otherwise the soymilk will overflow.
2. When beating beans, rice, etc., pay attention to laying it flat on the bottom of the cup. If there is a power failure during the work of the soymilk machine, don't press the function key immediately to work, which will cause the heater to paste the tube and damage the power cord, so you need to buy and replace it at a professional after-sales service office.