Current location - Recipe Complete Network - Diet recipes - Xunda price gas cooker price and notes introduction
Xunda price gas cooker price and notes introduction

XunDa is a collection of kitchen appliances and the whole cabinet as one of the domestic private brands, XunDa belongs to XunDa Technology Group Co. The company was founded in 1984, one of the founders of Mr. Wu Shangkui is a famous inventor, was awarded the "gas appliances gap hole cyclone combustion" patent technology, the technology is the world's first of this type of patented technology. Xunda brand has many types of household appliances, such as bath, range hoods, induction cookers, etc., the brand also has utensils, cabinets and other products. With the rabbit to see how much Xunda price!

Xunda built-in stainless steel gas cooker? Double-burner (out of warranty)

Reference price: 245 yuan

Panel material: stainless steel panel

Liquefied gas?2800PA

Natural gas?2000PA

Industrial gas?1000PA

Rated heat flow (kw): left?4.2,? Right 4.2

Panel size(mm):730*410

Opening size(mm):?630*350

XunDa Gas Stove?N9-HA Desktop Two-Way Double-Burner Gas Stove

Reference price:$380

Exterior size(mm). 715x390x125;

Heat load(KW):4.0kw, 4.0kw;

Ignition method:Piezo-electric ceramic ignition;

Type of gas:Liquefied petroleum gas, natural gas.

Shunde gas cooker N5-M with flame failure protection gas cooker? Tabletop? Single Stove

Reference Price:218RMB

Exterior Dimension(mm):311x410x98;

Heat Load(KW):4.0kw;

Ignition Mode:Piezoelectric Ceramic Ignition;

Type of Gas:Liquefied Petroleum Gas (LPG),Artificial Gas,Natural Gas.

Stove common abnormalities

A, ignition

(1) the gas master switch is not open, open the gas master switch

(2) battery power is insufficient, replace the battery

(3) the ignition needle grease and dirt, clean the ignition needle grease and dirt

(4) ignition needle position Improper, adjust the distance between the ignition needle and the fire cover 4-6mm, and aligned with the fire hole

(5) micro switch bad professional replacement

Two, gas leakage (or odor)

(1) the hose aging rupture or detachment of the replacement or reconnection of the hose

(2) the main fire of the stove head is not lit, accidental flame failure, to be dispersed after the gas is then ignited

(3) the inlet pipe sealing rubber ring aging, replace the rubber ring

three, the flame is abnormal

(1) red fire: air humidity, fumes, normal phenomenon

(2) yellow fire: the damper opening too small, open the damper

(3) fire cover fire hole dirt, clean up the fire cover

(4) cylinder in the liquefied petroleum gas is almost finished;, replace a bottle of Liquefied gas

Four, away from the flame, off the fire (flame from the fire hole)

(1) the damper opening is too large, adjust the damper

(2) gas pressure is too large, with liquefied petroleum gas cylinders, please ask a professional to adjust the pressure-reducing valve. With the pipeline gas gas main switch off a little smaller

(3) kitchen air flow is too fast, pumping too fierce, properly close the windows and doors, hoods playing weak gear

fifth, backfire (burning in the stove head)

(1) the fire cover did not put a good, put a good fire cover

(2) gas pressure is too low, if in order to save the gas shut off small, to open up the appropriate, the pipeline main switch open Large

(3) fire cover fire hole with overflow liquid and spoils, clean up the fire cover

(4) burning time is too long, the stove head temperature is too high, pause the use of the cooled down and then reuse

(5) the damper opening is too large, adjusting the pin damper

VI, short flame powerless

(1) low gas pressure, check the liquefied petroleum gas cylinder valve whether the open degree of Xiaohe pressure reducing valve is faulty

seven, the flame is easy to extinguish

(1)Ion sensor needle deviation from the flame, adjust the ion sensor needle

eight, flame out with noise

(1)Turn off the fire operating speed is too fast, turn off the fire a little slower

nine, combustion with a whistling sound

Nozzle has a burr, clean up the burr

ten, Automatic flame out

(1) ion induction protection, induction needle offset, fire cover to the position, adjust the induction needle to align the fire hole

(2) thermoelectric protection, thermocouple position is not right, adjust the dampers, adjust the thermocouple aligned with the fire hole

(3) inductance needle and grounding set (stainless steel parts) between water or spoils, use the inductance needle to touch the flame, clear off the water and spoils

(4)Induction needle broken, professional replacement

Shunde not only in the electrical appliances, the whole cabinet has a great development, its new energy research and development also has a very deep research. The products in new energy are: biogas power generation, domestic waste power generation and biomass energy generation. The products made by such a company with strong technical strength are also strong in function and service life. The above is the rabbit for you to introduce the content of the price of Xunda, the price is subject to change according to market changes, so I hope that the rabbit to organize the content can help you.

Tubapu online free for everyone to provide "each decoration offer, 1-4 local decoration company, 3 sets of decoration design program", and decoration to avoid pit strategy! Click on this link:/yezhu/zxbj-cszy.php?to8to_from=seo_zhidao_m_jiare&wb, you can get it for free Oh~